Sleep desaturation: comparison of two oximeters.

نویسندگان

  • Ha Trang
  • Souham Boureghda
  • Vivian Leske
چکیده

Oxygen saturation is measured by pulse oximetry during sleep studies. Body movements and peripheral vasoconstriction related to respiratory events may interfere with measurements by conventional oximeters. Our objective was to compare the detection rate of sleep desaturations by two oximeters, one of which used new motion-resistant technology. We studied 34 children (median age, 13 years; range, 3-18) with suspected sleep-disordered breathing. During polysomnography, oxygen saturation was measured by two oximeters set on fast mode: the motion-resistant Radical oximeter (2-sec averaging), and the conventional Nellcor N-200 oximeter (2-3-sec averaging). Respiratory events were identified based on airflow signal. The numbers of respiratory event-related desaturations > or =3% or > or =5% detected by each oximeter were determined. Valid desaturations were defined using the Nellcor plethysmographic waveform and the Radical signal-quality data. Hypoxemic respiratory events were those with associated valid desaturation. In total, 1,278 respiratory events were identified and pooled. Basal oxygen saturation measured just before event onset was not different between oximeters (Radical: 98%; range, 84-100; Nellcor: 97%; range, 86-100; P = ns). However, the Radical detected a greater number of valid desaturations than did the Nellcor for any level of desaturation (respectively, N = 651 and 476 desaturations > or =3%, P < 0.001; and N = 232 and 146 desaturations > or =5%, P = 0.01). Consequently, for each patient, the number of hypoxemic respiratory events per hour of sleep was greater using the Radical than using the Nellcor (P = 0.002, and P = 0.021, for desaturation > or =3% and > or =5%, respectively). In conclusion, standardized oximeter settings are required to achieve more accurate assessments of hypoxemia in children with sleep-disordered breathing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Two Oximeter Technologies in the Detection of Desaturation during Polysomnography

Introduction Different oximeters with different technologies are used in the sleep disorders laboratory to assess level of desaturation during sleep related respiratory events. The scoring of hypopneas based on the newly implemented definition by Medicare requires that there be a 4% or greater decrease in saturation associated with the event. We studied two different oximeter technologies to de...

متن کامل

The desaturation response time of finger pulse oximeters during mild hypothermia.

Pulse oximeters may delay displaying the correct oxygen saturation during the onset of hypoxia. We investigated the desaturation response times of pulse oximeter sensors (forehead, ear and finger) during vasoconstriction due to mild hypothermia and vasodilation caused by glyceryl trinitrate. Ten healthy male volunteers were given three hypoxic challenges of 3 min duration under differing experi...

متن کامل

Choice of oximeter affects apnea-hypopnea index.

STUDY OBJECTIVES Current Medicare guidelines include an apnea-hypopnea index (AHI) > or = 15 events per hour, in which all hypopneas must be associated with 4% desaturation, to qualify for reimbursement for therapy with continuous positive airway pressure (CPAP). The present data demonstrate the effect of pulse oximeter differences on AHI. DESIGN Prospective study, blinded analysis. SETTING...

متن کامل

Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?

Objective. To assess the diagnostic ability of WristOx 3100 using its three different recording settings in patients with suspected obstructive sleep apnea syndrome (OSAS). Methods. All participants (135) performed the oximetry (three oximeters WristOx 3100) and polysomnography (PSG) simultaneously in the sleep laboratory. Both recordings were interpreted blindly. Each oximeter was set to one o...

متن کامل

Use of two oximeters to investigate a method of movement artefact rejection using photoplethysmographic signals.

Oxygen haemoglobin saturations and plethysmograph signal amplitudes were recorded from two oximeters placed on the fingers and toes of 10 patients undergoing oesophagectomy, to assess a method of removing motion artefact from saturation recordings. By examining changes in the plethysmograph amplitude that preceded changes in saturation, episodes of desaturation caused by movement artefacts were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pediatric pulmonology

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2004