Essential mixed cryoglobulinaemia with false-positive serological tests for syphilis.

نویسندگان

  • R R Jones
  • C Pusey
  • J Schifferli
  • N A Johnston
چکیده

Analysis of serum from a patient with cutaneous leukocytoclastic vasculitis showed a mixed cryoglobulin with a monoclonal IgM kappa-antiglobulin component (6.5 mg/ml), strong rheumatoid factor activity (latex titre 1/5000), and positive serological tests for syphilis (fluorescent treponemal antibody-absorbed and Treponema pallidum haemagglutination assay). After removal of antiglobulin activity by immunoabsorption with heat-aggregated gammaglobulin all serological test results for treponemal infection became negative. Serological tests for syphilis and rheumatoid factor on the supernatant from whole serum (minus cryoglobulin) remained positive though at a lower titre (latex 1/1250). Cryoglobulin isolated from whole serum retained rheumatoid and TPHA reactivity but was negative in the FTA-ABS test. The IgM and IgG cryoglobulin components purified by gel filtration on Sepharose showed no antitreponemal reactivity even when tested individually. Reducing the concentration of cryoglobulin to 1.5 mg/ml by plasma exchange converted the test results for syphilis to doubtful-positive or negative. These results indicated that high concentrations of antiglobulin activity may be associated with falsely positive specific antitreponemal test results and that this phenomenon depends on the concentration of cryoglobulin in the test sample.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chronic biological false-positive reactions to serological tests for syphilis in blood donors.

Problem sera from 375 blood donors were investigated for biological false-positive reactions to serological tests for syphilis. Problem sera are those sera in which submitting laboratories have found a reactive result to a screening test for syphilis. On each serum a cardiolipin Wassermann reaction, a Venereal Disease Research Laboratory test, a Reiter protein-complement fixation test, a Trepon...

متن کامل

An Antibody against Stored Blood Associated with Cirrhosis of the Liver and False-positive Serological Tests for Syphilis.

A case of cirrhosis of the liver, associated with false-positive serological tests for syphilis and an antibody active against stored red cells, is presented. Methods used in the identification of the ;stored red cell' antibody are described.

متن کامل

Ageing and false positive reactions for syphilis.

Biological false positive reactors for syphilis (BFP) are defined as those patients having reagin demonstrated by positive serological tests for syphilis and non-reactive treponemal antibody tests. Acute biological false-positive reactions (ABFP) terminate in 1 to 6 months. Patients in whom reagin persists longer than 6 months are considered to have chronic reactions (CBFP). Harvey (1962) stres...

متن کامل

The biological false positive reaction to serological tests for syphilis.

Acute and chronic biological false positive reactions to serological tests for syphilis are discussed. Three cases are presented, one showing an acute and one a chronic reaction, and one in which it was not possible to determine if the reaction was acute or chronic. Once a biological false positive reaction is found, serum from the patient should be tested at intervals for at least six months t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of venereal diseases

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 1983