Adverse reaction to metal debris with concomitant incidental crystalline arthropathy in hip arthroplasty
نویسندگان
چکیده
Adverse reaction to metal debris (ARMD) is a known cause of failed metal in hip arthroplasty. Diagnosis of this type of prosthesis failure may be difficult, and the hallmark is an abnormally elevated serum cobalt level. Concomitant diagnoses may also be present, such as infection, instability, and loosening, and this may confuse interpretation of abnormal laboratories. We present here, for the first time, 2 patients with ARMD and crystalline arthropathy. In each case, the patient chose surgery for ARMD, with resolution of symptoms and no recurrence of the crystalline arthropathy. We present these cases to alert the orthopaedist that crystalline arthropathy may be present at the same time as ARMD, but is likely not the primary cause of symptoms.
منابع مشابه
Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management
Recent alarming joint registry data highlighting increased revision rates has prompted further research into the area of metal-on-metal hip replacements and resurfacings. This review article examines the latest literature on the topic of adverse reactions to metal debris and summarises the most up-to-date guidelines on patient management. Adverse reactions to metal debris can cause significant ...
متن کاملSilent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-re...
متن کاملAdverse reaction to metal debris in a painful hemiarthroplasty of the hip
Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all ...
متن کاملImmune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty
BACKGROUND The purpose of the present study was to determine whether T cell-mediated type IV hypersensitivity reactions could be a major cause of adverse reaction to metal debris (ARMD) after metal-on-metal total hip arthroplasty (THA). METHODS Thirteen patients (1 man and 12 women; mean age 68 years, age range 60 to 83 years) with ARMD underwent revision surgery following metal-on-metal THA ...
متن کاملOne-component revision of failed hip resurfacing from adverse reaction to metal wear debris.
This study assessed the results of 90 one-component revisions for failed hip resurfacing due to adverse reaction to metal wear debris (76 acetabular, 14 femoral). Patients with a femoral head size 40-45 mm (n=33) received a two-piece titanium meshed shell with a cross-linked polyethylene liner and patients with femoral head size 46-54 mm (n=43) received metal-on-metal components. Patients with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2017