PURPOSE This study evaluates the accuracy, reproducibility, and efficiency of FASTPAC, a new fast strategy for automated perimetry using 3-dB steps with single threshold crossing, compared to the standard 4-2 dB full threshold strategy by means of computer simulations. METHOD An "artificial patient" module was developed to create responses to stimuli by a Monte-Carlo technique from a given probability distribution. The authors performed 10,200 simulations with threshold values ranging from 0 to 50 dB. RESULTS Results demonstrate an 18% decrease in the number of presentations per threshold determination, which is equal to a similar reduction in testing time. For both strategies, there is a considerable influence of the starting deviation (difference between starting value and actual threshold) on threshold error (difference between estimated threshold and actual threshold): negative starting deviations lead to negative threshold errors and vice versa. This relationship is more pronounced for FASTPAC (slope 0.18 dB/dB, P < 0.0001) than for the full-threshold strategy (slope 0.13 dB/dB, P < 0.0001). In addition, fluctuations of the determined thresholds, described as the distance between the 16th and 84th percentiles of the threshold errors, increase with increasing absolute starting deviations. This is particularly true of FASTPAC: CONCLUSIONS The influence of the starting value on the threshold determination may lead to a considerable underestimation of visual field defects, accompanied by a higher fluctuation. This is an intrinsic property of both staircase procedures. FASTPAC, however, is more affected than the standard 4-2 dB full-threshold strategy. FASTPAC, therefore, provides time reduction at the expense of accuracy and reliability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucomatous visual fields. FASTPAC versus full threshold strategy of the Humphrey Field Analyzer.

PURPOSE This study examined how FASTPAC, a fast strategy for the Humphrey Field Analyzer (HFA), compares to the standard 4/2-dB full threshold strategy in patients with glaucoma. METHOD The author tested one eye each of 50 patients with glaucoma (23 with only relative defects, 27 with at least one absolute defect; age range, 25 to 79 years; median age, 61.5 years) with both strategies using p...

متن کامل

The SITA perimetric threshold algorithms in glaucoma.

PURPOSE To determine the within-visit between-algorithm and the within-algorithm between-visit differences in sensitivity for the SITA Standard, SITA Fast, FASTPAC, and Full Threshold algorithms in stable primary open angle glaucoma. METHODS One designated eye from each of 29 patients (age 67.3 +/- 10.2 years; mean +/- SD) experienced in automated perimetry was examined with the four algorith...

متن کامل

Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.

PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...

متن کامل

Different strategies for Humphrey automated perimetry: FASTPAC, SITA standard and SITA fast in normal subjects and glaucoma patients.

PURPOSE To evaluate the influence on examination time and test quality of the recently introduced SITA strategies of the Humphrey Field Analyzer. METHODS The sample consisted of 41 subjects (19 normal subjects and 22 glaucoma patients), all experienced in automated perimetry, ranging in age from 24 to 83 years. One eye of each patient was examined with the HC30-2 program using the FASTPAC (FP...

متن کامل

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...