[Exploring spatiotemporal patterns of epileptiform discharge in hippocampal slice using multi-electrode arrays].

نویسندگان

  • Jian-Sheng Liu
  • Xin-Wei Gong
  • Hai-Qing Gong
  • Pu-Ming Zhang
  • Pei-Ji Liang
  • Qin-Chi Lu
چکیده

To investigate the spatiotemporal properties of epileptiform activity in vitro, 400 microm-thick transverse hippocampal slices were prepared from juvenile rat and planar multi-electrode array (MEA) containing 60 electrodes was used to record the electrical activity induced by bath application of high potassium artificial cerebrospinal fluid (ACSF) on slices. Following successful induction of epileptiform bursts, phenobarbital sodium was applied to test for its inhibitory effects on bursting activity in different regions of slice. Region-specific characteristics of epileptiform activity and anticonvulsant actions of phenobarbital sodium in the hippocampal network were determined by comparing the population activity obtained from MEA. The results showed that: (1) 15 min after high-K+ ACSF application, rhythmic and synchronous epileptiform bursts could be detected from all CA sub-regions. Quantitative analysis indicates that the firing patterns of different CA sub-regions were not statistically different (P>0.05). However, no bursting activity was recorded from granular cells in dentate gyrus, only sparse spikes were observed, with frequency significantly lower than that in CA regions (P<0.05). (2) The high-K+-induced bursting activity could last for more than 40 min with stable bursting activities. (3) Bath application of 60 micromol/L phenobarbital sodium inhibited the bursting activities on hippocampal slice. Bursting activities in CA3c and CA1 were firstly suppressed. 10 min after the phenobarbital sodium application, strong bursting activities persisted only in some of pyramidal cells in CA3a and CA3b. These results show that MEA could be applied for studying the spatial and temporal properties of epileptiform activity in vitro, as well as the region-specific effects of anti-epileptic drugs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the Entorhinal Cortex on Ictal Discharges in Low-Mg2+-Induced Epileptic Hippocampal Slice Models

The hippocampus plays an important role in the genesis of mesial temporal lobe epilepsy, and the entorhinal cortex (EC) may affect the hippocampal network activity because of the heavy interconnection between them. However, the mechanism by which the EC affects the discharge patterns and the transmission mode of epileptiform discharges within the hippocampus needs further study. Here, multielec...

متن کامل

Millimeter-scale epileptiform spike propagation patterns and their relationship to seizures.

OBJECTIVE Current mapping of epileptic networks in patients prior to epilepsy surgery utilizes electrode arrays with sparse spatial sampling (∼1.0 cm inter-electrode spacing). Recent research demonstrates that sub-millimeter, cortical-column-scale domains have a role in seizure generation that may be clinically significant. We use high-resolution, active, flexible surface electrode arrays with ...

متن کامل

Imaging of 4-AP-induced, GABA(A)-dependent spontaneous synchronized activity mediated by the hippocampal interneuron network.

Under conditions of increased excitability, such as application of the K(+) channel blocker 4-aminopyridine (4-AP, 100 microM), interneurons in the hippocampal slice show an additional form of synchronized activity that is distinct from the ictal and interictal epileptiform activity induced by these manipulations. In principal neurons, i.e., pyramidal and granule cells, this synchronized intern...

متن کامل

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Large-scale, high-resolution electrophysiological imaging of field potentials in brain slices with microelectronic multielectrode arrays

Multielectrode arrays (MEAs) are extensively used for electrophysiological studies on brain slices, but the spatial resolution and field of recording of conventional arrays are limited by the low number of electrodes available. Here, we present a large-scale array recording simultaneously from 4096 electrodes used to study propagating spontaneous and evoked network activity in acute murine cort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Sheng li xue bao : [Acta physiologica Sinica]

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2010