Active stabilization of ion trap radiofrequency potentials.

نویسندگان

  • K G Johnson
  • J D Wong-Campos
  • A Restelli
  • K A Landsman
  • B Neyenhuis
  • J Mizrahi
  • C Monroe
چکیده

We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Planar Ion Trap Geometry for Microfabrication

We describe a novel high aspect ratio radiofrequency linear ion trap geometry that is amenable to modern microfabrication techniques. The ion trap electrode structure consists of a pair of stacked conducting cantilevers resulting in confining fields that take the form of fringe fields from parallel plate capacitors. The confining potentials are modeled both analytically and numerically. This io...

متن کامل

Stylus ion trap for enhanced access and sensing

Small, controllable, highly accessible quantum systems can serve as probes at the single-quantum level to study a number of physical effects, for example in quantum optics or for electricand magnetic-field sensing. The applicability of trapped atomic ions as probes is highly dependent on the measurement situation at hand and thus calls for specialized traps. Previous approaches for ion traps wi...

متن کامل

Novel ion traps using planar resistive electrodes: implications for miniaturized mass analyzers.

In radiofrequency ion traps, electric fields are produced by applying time-varying potentials between machined metal electrodes. The electrode shape constitutes a boundary condition and defines the field shape. This paper presents a new approach to making ion traps in which the electrodes consist of two ceramic discs, the facing surfaces of which are lithographically imprinted with sets of conc...

متن کامل

Linear ion traps in mass spectrometry.

Linear ion traps are finding new applications in many areas of mass spectrometry. In a linear ion trap, ions are confined radially by a two-dimensional (2D) radio frequency (RF) field, and axially by stopping potentials applied to end electrodes. This review focuses on linear ion trap instrumentation. Potentials and ion motion in linear multipole fields and methods of ion trapping, cooling, exc...

متن کامل

A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is to accumulate the 60-keV continuous ISOLDE ion beam with high efficiency and to convert it into low-energy low-emittance ion pulses. The efficiency was foun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 2016