Comparison of protein values in cerebrospinal fluid by nephelometry and radial immunodiffusion.

نویسندگان

  • J C Joseph
  • E W Bermes
چکیده

Various parameters of three radial immunodiffusion systems, a kinetic nephelometer and two laser nephelometers were compared in a measurement of IgG and albumin in cerebrospinal fluid. Greater precision for IgG and albumin determinations was found with two RID systems. Correlation coefficients between methods ranged from 0.71 to 0.94. The generally poor correlations of methods, combined with the results of accuracy studies employing WHO standard reference dilutions and proportional errors demonstrated by linear regression equations, illustrate graphically the need for standardization in the field of immunochemical determinations. Our preliminary studies of the IgG/Alb ratio in cerebrospinal fluid of multiple sclerosis patients agreed with the work of others. In each case, the ratio was elevated or borderline high.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human African trypanosomiasis: a latex agglutination field test for quantifying IgM in cerebrospinal fluid.

LATEX/IgM, a rapid agglutination test for the semi-quantitative detection of IgM in cerebrospinal fluid of patients with African trypanosomiasis, is described in this article. The lyophilized reagent has been designed for field use and remains stable at 45 degrees C for one year. The test has been evaluated on cerebrospinal fluid samples from trypanosome-infected and non-infected patients, by c...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.

Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA prote...

متن کامل

Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radi...

متن کامل

Comparison of electroimmunodiffusion and radial immunodiffusion for measurement of IgG in the laboratory diagnosis of multiple sclerosis.

The detection of a supranormal quantity of immunoglobulin G (lgG) in cerebrospinal fluid is valuable in diagnosis of multiple sclerosis. In a previously published study of over 300 patients, including 46 patients with a clinical diagnosis of multiple sclerosis, 74% of the patients were found to have an abnormally high lgG value, expressed as a ratio of lgG/albumin, by the reliable method of ele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 1979