Reproducibility and minimal detectable change of three-dimensional kinematic analysis of reaching tasks in people with hemiparesis after stroke.

نویسندگان

  • Joanne M Wagner
  • Jennifer A Rhodes
  • Carolynn Patten
چکیده

BACKGROUND AND PURPOSE Three-dimensional kinematic analysis of reaching has emerged as an evaluative measure of upper-extremity motor performance in people after stroke. However, the psychometric properties supporting the use of kinematic data for evaluating longitudinal change in motor performance have not been established. The objective of this study was to determine, in a test-retest reliability manner, the reproducibility and minimal detectable change for reaching kinematics in people after stroke. SUBJECTS AND METHODS Fourteen participants with hemiparesis after stroke performed forward reaching tasks on 2 occasions 37.3 (SD=9.8) days apart. At each session, participants performed 4 forward reaching tasks produced by the combination of 2 target heights (low and high [109 and 153 cm from the floor, respectively]) and 2 instructed movement speeds (self-selected and as fast as possible). Two analytical methods were used to calculate kinematic parameters. RESULTS Relative reliability (intraclass correlation coefficient) ranged from .04 to .99, and absolute reliability (standard error of measurement) ranged from 2.7% to 76.8%, depending on the kinematic variable, the demands of the motor task (target height and movement speed), and the analytical method. Bland-Altman analysis, a statistical method used to assess the repeatability of a method, revealed few systematic errors between sessions. The minimal detectable change ranged from 7.4% to 98.9%. DISCUSSION AND CONCLUSION Depending on the demands of the motor task and the analytical method, most kinematic outcome measures (such as peak hand velocity, endpoint error, reach extent, maximum shoulder flexion range of motion, and minimum elbow extension range of motion) are reliable measures of motor performance in people after stroke. However, because of the magnitude of within-subject measurement error, some variables (such as peak hand velocity, time to peak hand velocity, and movement time) must change considerably (>50%) to indicate a real change in individual participants. The results of our reliability analysis, which are based on our cohort of participants with hemiparesis after stroke and our specific paradigm, may not be generalizable to different subpopulations of people with hemiparesis after stroke or to the myriad movement tasks and kinematic variables used for the assessment of reaching performance in people after stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...

متن کامل

The kinematics of upper extremity reaching: a reliability study on people with and without shoulder impingement syndrome

BACKGROUND Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objecti...

متن کامل

Measurement Properties of Physical Therapy Patient Satisfaction Questionnaire in an Iranian Musculoskeletal Population

Background: A valid and reliable tool that could measure patient satisfaction with physical therapy care for Persian-speaking patients will improve communication and enhance the involvement of people in research on health care quality and disparities. We aimed to evaluate the psychometric properties of the Persian version of the physical therapy patient satisfaction questionnaire (PTPSQ). Meth...

متن کامل

Development and validation of a scale for rating motor compensations used for reaching in patients with hemiparesis: the reaching performance scale.

BACKGROUND AND PURPOSE Recent movement analysis studies have described compensatory movement strategies used by people with hemiparesis secondary to stroke during reaching and grasping tasks. The purpose of this article is to describe the development of a new scale--the Reaching Performance Scale (RPS)--for assessing compensatory movements for upper-extremity reaching in people with hemiparesis...

متن کامل

Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical therapy

دوره 88 5  شماره 

صفحات  -

تاریخ انتشار 2008