Optimization and Comparison of Multiple MALDI Matrix Application Methods for Small Molecule Mass Spectrometric Imaging

نویسندگان

  • Erin Gemperline
  • Stephanie Rawson
  • Lingjun Li
چکیده

The matrix application technique is critical to the success of a matrix-assisted laser desorption/ionization (MALDI) experiment. This work presents a systematic study aiming to evaluate three different matrix application techniques for MALDI mass spectrometric imaging (MSI) of endogenous metabolites from legume plant, Medicago truncatula, root nodules. Airbrush, automatic sprayer, and sublimation matrix application methods were optimized individually for detection of metabolites in the positive ionization mode exploiting the two most widely used MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA). Analytical reproducibility and analyte diffusion were examined and compared side-by-side for each method. When using DHB, the optimized method developed for the automatic matrix sprayer system resulted in approximately double the number of metabolites detected when compared to sublimation and airbrush. The automatic sprayer method also showed more reproducible results and less analyte diffusion than the airbrush method. Sublimation matrix deposition yielded high spatial resolution and reproducibility but fewer analytes in the higher m/z range (500-1000 m/z). When the samples were placed in a humidity chamber after sublimation, there was enhanced detection of higher mass metabolites but increased analyte diffusion in the lower mass range. When using CHCA, the optimized automatic sprayer method and humidified sublimation method resulted in double the number of metabolites detected compared to standard airbrush method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of NIMS and MALDI platforms for neuropeptide and lipid mass spectrometric imaging in C. borealis brain tissue.

Nanostructure-initiator mass spectrometry (NIMS) is a recently developed matrix-free laser desorption/ionization technique that has shown promise for peptide analyses. It is also useful in mass spectrometric imaging (MSI) studies of small molecule drugs, metabolites, and lipids, minimizing analyte diffusion caused by matrix application. In this study, NIMS and matrix-assisted laser desorption/i...

متن کامل

MALDI-mass spectrometric imaging for the investigation of metabolites in Medicago truncatula root nodules.

Most techniques used to study small molecules, such as pharmaceutical drugs or endogenous metabolites, employ tissue extracts which require the homogenization of the tissue of interest that could potentially cause changes in the metabolic pathways being studied(1). Mass spectrometric imaging (MSI) is a powerful analytical tool that can provide spatial information of analytes within intact slice...

متن کامل

Imaging Mass Spectrometric Analysis of Neurotransmitters: A Review.

Imaging mass spectrometry (IMS) is a toolbox of versatile techniques that enable us to investigate analytes in samples at molecular level. In recent years, IMS, and especially matrix-assisted laser desorption/ionisation (MALDI), has been used to visualise a wide range of metabolites in biological samples. Simultaneous visualisation of the spatial distribution of metabolites in a single sample w...

متن کامل

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS

Matrix Assisted Laser Desorption Ionization (MALDI) Mass Spectrometry (MS) with a computer-controlled xy-stage in the ionization source can be used to detect the presence, approximate amount and location of small molecules, lipids, peptides and proteins in tissue samples through in vitro molecular imaging, often referred to as MALDI imaging. Both MALDI Time-of-flight/Time-of-flight (MALDI-TOF/T...

متن کامل

MALDI Tissue Imaging of Drugs with the ultraflex MALDI TOF/TOF

MALDI-TOF MS has previously been used for imaging of large peptides and proteins embedded in tissue sections. This imaging technique is not limited to larger molecules, but can also be used to measure the presence of small molecules directly from tissue. However, for small molecule imaging the method of choice is a selected reaction monitoring approach in MS/MS mode.The benefits of parent ion i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2014