Biomechanical analysis of posterior cruciate ligament reconstruction with aperture femoral fixation.

نویسندگان

  • Amar Mutnal
  • Brian M Leo
  • Luis Vargas
  • Robb W Colbrunn
  • Robert S Butler
  • John W Uribe
چکیده

The goal of this study was to determine whether single-tunnel-double-bundle-equivalent posterior cruciate ligament (PCL) reconstruction using an aperture femoral fixation device better replicated normal knee kinematics than single-bundle reconstruction. Eight fresh-frozen human cadaver knees underwent arthroscopically assisted PCL reconstruction and were examined with a robotic testing system to assess knee joint kinematics under combinations of applied internal, neutral, and external rotational tibial torque and anteroposterior translational forces at 0°, 30°, 60°, 90°, and 120° flexion. Three conditions were tested: (1) intact PCL; (2) single-tunnel PCL reconstruction with anterolateral and posteromedial bundle fixation at 90°/90° (single bundle); and (3) 90°/0° (double-bundle equivalent), respectively. Posterior tibial translation was the primary outcome measure. Compared with the intact knee, double-bundle-equivalent reconstruction under external tibial torque allowed greater posterior translation across the flexion arc as a whole (P=.025) and at 30° flexion (P=.027) when results were stratified by flexion angle. No other kinematic differences were found with single-bundle or double-bundle-equivalent fixation, including mediolateral translation and both coupled and isolated tibial rotation (P>.05). Single-bundle PCL reconstruction closely approximated native knee rotational and translational kinematics, whereas double-bundle-equivalent reconstruction permitted increased posterior translation with applied external tibial torque, particularly at lower flexion angles. Single-bundle PCL reconstruction provides knee stability similar to the intact condition, making it a practical alternative to conventional double-bundle PCL reconstruction. The authors found that double-bundle-equivalent reconstruction provided no advantage to justify its clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femoral Aperture Fixation Improves Anterior Cruciate Ligament Graft Function When Added to Cortical Suspensory Fixation

BACKGROUND Recommendations for bone tunnel placement during anterior cruciate ligament (ACL) reconstruction have become more precise. However, these recommendations differ neither with the choice of graft nor with the method of fixation used. The influence of the method of femoral fixation used on the biomechanical function of a soft tissue ACL graft remains unknown. HYPOTHESIS Our null hypot...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

SIMULTANEOUS RECONSTRUCTION OF MEDIAL COLLATERAL LIGAMENT AND POSTERIOR CRUCIATE LIGAMENT VIA SINGLE MEDIAL FEMORAL TUNNEL : A MODIFIED TECHNIQUE AND CASE SERIES

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

A comparison of functional outcome between bioabsorbable interference screw and endobutton fixation on femur in arthroscopic anterior cruciate Ligament reconstruction

Introduction: Arthroscopic Anterior Cruciate Ligament [ACL] reconstruction is very commonly done procedure in recent times {1}. The graft fixation methods vary from aperture fixation [Interference screws] to suspensory fixation methods [Endobutton]. This is a Prospective non randomised clinical study of arthroscopic ACL reconstruction comparing the functional results between aperture fixation a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 38 1  شماره 

صفحات  -