Experimental results on gravity driven fully condensing flows in vertical tubes, their agreement with theory, and their differences with shear driven flows' boundary-condition sensitivities
نویسنده
چکیده
This paper synthesizes experimental results reported here with computational results towards development of a reliable heat transfer correlation for a specific annular condensation flow regime inside a vertical tube. For fully condensing flows of pure vapor (FC-72) inside a vertical cylindrical tube of 6.6 mm diameter and 0.7 m length, the experimental measurements are shown to yield values of average heat transfer co-efficient, and approximate length of full condensation. The experimental conditions cover: mass flux G over a range of 2.9 kg/m-s ≤ G ≤ 87.7 kg/m-s, temperature difference ∆T (saturation temperature at the inlet pressure minus the mean condensing surface temperature) of 5 oC to 45 oC, and cases for which the length of full condensation xFC is in the range of 0 < xFC < 0.7 m. The range of flow conditions over which there is good agreement (within 15%) with the theory and its modeling assumptions has been identified. Additionally, the ranges of flow conditions for which there are significant discrepancies (between 15 -30% and greater than 30%) with theory have also been identified. The paper also refers to a brief set of key experimental results with regard to sensitivity of the flow to timevarying or quasi-steady (i.e. steady in the mean) impositions of pressure at both the inlet and the outlet. The experimental results support the updated theoretical/computational results that gravity dominated condensing flows do not allow such elliptic impositions, whereas, shear driven condensing flows (representative experimental results are also presented) are sensitive to such impositions.
منابع مشابه
A Quasi One-dimensional Method and Results for Steady Annular/stratified Shear and Gravity Driven Condensing Flows
This paper presents an effective quasi one-dimensional (1-D) computational simulation methodology and some important results for steady annular/stratified (or film wise) internal condensing flows of pure vapor. Though the approach is strictly valid for smooth, laminar vapor/laminar condensate flows, it is also approximately valid for laminar condensate and turbulent vapor which are laminar in t...
متن کاملNumerical analysis of gas flows in a microchannel using the Cascaded Lattice Boltzmann Method with varying Bosanquet parameter
Abstract. In this paper, a Cascaded Lattice Boltzmann Method with second order slip boundary conditions is developed to study gas flows in a microchannel in the slip and transition flow regimes with a wide range of Knudsen numbers. For the first time the effect of wall confinement is considered on the effective mean free path of the gas molecules using a function with nonconstant Bosanquet para...
متن کاملPrediction and Control of Internal Condensing Flows in the Experimental Context of their Inlet Condition Sensitivities
The reported experimental results involve fully condensing flows of pure FC-72 vapor on a horizontal condensing surface (316 stainless steel) which is the bottom surface (wall) of a rectangular cross-section duct of 2 mm height, 15 mm width, and 1 m length. The sides and top of the duct are made of clear plastic. The experimental system in which this condenser is used is able to control steadyi...
متن کاملThe effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows by Lattice-Boltzmann method
The aim of this study is to investigate the effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows in the context of single relaxation time Lattice Boltzmann method (SRT-LBM). The fluid flows are simulated using regularized, no-slip, Zou-He and bounce back boundary conditions for straight surfaces in a lid driven cavity and the two-dimensional flow ...
متن کاملEffects of Gravity, Shear and Surface Tension in Internal Condensing Flows: Results From Direct Computational Simulations
The paper presents accurate numerical solutions of the full two-dimensional governing equations for steady and unsteady laminar/laminar internal condensing flows. The results relate to issues of better design and integration of condenser-sections in thermal management systems (looped heat pipes, etc.). The flow geometry, in normal or zero gravity, is chosen to be the inside of a channel with fi...