Fixation Strategies to Prevent Screw Cut-Out and Malreduction in Proximal Humeral Fracture Fixation

نویسندگان

  • Surena Namdari
  • Adam J. Lipman
  • Eric T. Ricchetti
  • Fotios P. Tjoumakaris
  • G. Russell Huffman
  • Samir Mehta
چکیده

Fixation of proximal humerus fractures with precontoured, fixed angle devices has improved operative management of these difficult injuries, particularly in patients with osteoporosis. However, recent data has revealed that fixation with these constructs is not without complications, particularly screw cut-out and loss of reduction. Multiple strategies have been developed to decrease the number of complications. We offer a surgical technique combining suture augmentation of the proximal humerus with locked plate fixation utilizing short screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

       Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize th...

متن کامل

Locking plate fixation for proximal humerus fractures.

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

متن کامل

Injury to the axillary artery, a complication of fixation using a locking plate.

The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary artery necessitating urgent removal of the implant.

متن کامل

Is Loss of Fixation Following Locked Plating of Proximal Humeral Fractures Related to the Number of Screws and Their Positions in the Humeral Head?

The aim of the study was to examine the correlation between the chosen position of screws and the complications observed in patients who underwent locked plating of proximal humeral fractures. We evaluated radiographs of 367 patients treated by locked-plating for proximal humeral fractures. Radiographs were taken at one day, 6 weeks, 3 months and 6 months after surgery, and were analyzed for se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012