A prospective evaluation of the contribution of ambient temperatures and transport times on infrared thermometry readings of intravenous fluids utilized in EMS patients

نویسندگان

  • Jeremy Joslin
  • Andrew Fisher
  • Susan Wojcik
  • Derek R Cooney
چکیده

BACKGROUND During cold weather months in much of the country, the temperatures in which prehospital care is delivered creates the potential for inadvertently cool intravenous fluids to be administered to patients during their transport and care by emergency medical services (EMS). There is some potential for patient harm from unintentional infusion of cool intravenous fluids. Prehospital providers in these cold weather environments are likely using fluids that are well below room temperature when prehospital intravenous fluid (IVF) warming techniques are not being employed. It was hypothesized that cold ambient temperatures during winter months in the study location would lead to the inadvertent infusion of cold intravenous fluids during prehospital patient care. METHODS Trained student research assistants obtained three sequential temperature measurements using an infrared thermometer in a convenience sample of intravenous fluid bags connected to patients arriving via EMS during two consecutive winter seasons (2011 to 2013) at our receiving hospital in Syracuse, New York. Intravenous fluids contained in anything other than a standard polyvinyl chloride bag were not measured and were not included in the study. Outdoor temperature was collected by referencing National Weather Service online data at the time of arrival. Official transport times from the scene to the emergency department (ED) and other demographic data was collected from the EMS provider or their patient care record at the time of EMS interaction. RESULTS Twenty-three intravenous fluid bag temperatures were collected and analyzed. Outdoor temperature was significantly related to the temperature of the intravenous fluid being administered, b = 0.69, t(21) = 4.3, p < 0.001. Transport time did not predict the measured intravenous fluid temperatures, b = 0.12, t(20) = 0.55, p < 0.6. CONCLUSIONS Use of unwarmed intravenous fluid in the prehospital environment during times of cold ambient temperatures can lead to the infusion of cool intravenous fluid and may result in harm to patients. Short transport times do not limit this risk. Emergency departments should not rely on EMS agencies' use of intravenous fluid warming techniques and should consider replacing EMS intravenous fluids upon ED arrival to ensure patient safety.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ASSESSMENT OF THE EFFECTS OF INCREASED INTRAVENOUS HYDRATION ON THE COURSE OF LABOR IN NULLIPAROUS TERM PREGNANCIES

Physiologists have shown that increased fluids improve skeletal muscle performance in prolonged exercise.Typical orders provide for 125 mL of intravenous fluids per hour in patients taking limited oral fluids during labor. Our purpose in this study was to determine whether increased intravenous fluids affect the progress of labor. In a prospective randomized institutional clinical trial, on...

متن کامل

A comparative study on the effects of warm intravenous fluids, intravenous pethidine, and combined warm intravenous fluids and humid-warm oxygen on hemodynamic parameters after general anesthesia in patients with shivering in the recovery room

Introduction: Pethidine is commonly used to treat shivering after general anesthesia (GA), yet respiratory depression may subsequently occur. Warming methods such as warm fluids and/or humid-warm oxygen inhalation can reduce shivering after GA. This randomized clinical trial aimed to compare the effects of three different methods on the reduction of shivering and their hemodynamic and respirato...

متن کامل

CO2-H2O, Highly Saline and Carbonic Fluids from the Mesozoic Mashhad Granitoids, NE Iran

The Mesozoic Mashhad granitoid plutons have intruded into ophiolite complexes, meta-sediments and pyroclastics in the Binalood region, located SW of Mashad city in the NE part of Iran. Based on petrography and geochemistry, the Mashhad granitoids have been classified into 1) grey granite, 2) pink granite, 3) muscovite granite, 4) granodiorite and 5) pegmatite and quartz veins. Granitoids show t...

متن کامل

Digitized infrared segmental thermometry: time requirements for stable recordings.

OBJECTIVES Digitized infrared segmental thermometry (DIST) is a method for measuring and recording skin surface body temperatures. The project evaluated the required length of time for patients to acclimatize their core body temperature to ambient conditions to obtain stable DIST readings. METHODS Seventeen subjects were allowed a 20-minute acclimatizing period in a temperature-controlled roo...

متن کامل

ASSESSMENT OF THE EFFECTS OF INCREASED INTRA VENOUS HYDRATION ON THE COURSE OF LABOR IN NULLIPAROUS TERM PREGNANCIES

 ABSTRACT Physiologists have shown that increased fluids improve skeletal muscle performance in prolonged exercise. Typical orders provide for 125 mL of intravenous fluids per hour in patients taking limited oral fluids during labor. Our purpose in this study was to determine whether increased intravenous fluids affect the progress oflabor. In a prospective randomized institutional clinical tri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014