Complete intracranial arterial and venous blood flow evaluation with 4D flow MR imaging.

نویسندگان

  • M D Hope
  • D D Purcell
  • T A Hope
  • C von Morze
  • D B Vigneron
  • M T Alley
  • W P Dillon
چکیده

SUMMARY Time-resolved, 3D velocity-encoded MR imaging (4D Flow) allows for the acquisition of dynamic, multidirectional data on blood flow and has recently been used for the evaluation of intracranial arterial flow. Using a 3T system with optimization of both temporal resolution and k-space subsampling with a combination of parallel imaging and cut-corner acquisition, we present the clinical assessment of a patient with an arteriovenous malformation by providing complete intracranial arterial and venous coverage in a reasonable scan time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracranial 4D flow MRI: toward individualized assessment of arteriovenous malformation hemodynamics and treatment-induced changes.

BACKGROUND AND PURPOSE Arteriovenous malformations are an important etiology of hemorrhagic stroke. However, current imaging modalities and risk do not provide insights into individual AVM hemodynamics and its role in pathophysiology. The aims of this study are to determine whether intracranial 4D flow MR imaging can provide insights into arteriovenous malformation hemodynamics independent of t...

متن کامل

Pressure Mapping and Hemodynamic Assessment of Intracranial Dural Sinuses and Dural Arteriovenous Fistulas with 4D Flow MRI.

The feasibility of 4D flow MR imaging to visualize flow patterns and generate relative pressure maps in the dural venous sinus in healthy subjects (n = 60) and patients with dural arteriovenous fistulas (n = 7) was investigated. Dural venous drainage was classified based on torcular Herophili anatomy by using 4D flow MR imaging-derived angiograms and magnitude images. Subjects were scanned in a...

متن کامل

In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

SUMMARY We evaluated electrocardiogram-synchronized flow-sensitized 4-dimensional MR imaging at 3T in combination with advanced 3D visualization strategies to ascertain its feasibility for the assessment of local intracranial blood-flow patterns in vivo. In large arteries of healthy volunteers, the temporal and spatial evolution of blood flow was successfully visualized and revealed--for exampl...

متن کامل

Comparison of blood flow velocity quantification by 4D flow MR imaging with ultrasound at the carotid bifurcation.

BACKGROUND AND PURPOSE 4D flow MR imaging is an emerging technique that allows visualization and quantification of 3D blood flow in vivo. However, representative studies evaluating its accuracy are lacking. Therefore, we compared blood flow quantification by using 4D flow MR imaging with US within the carotid bifurcation. MATERIALS AND METHODS Thirty-two healthy volunteers (age 25.3 ± 3.4 yea...

متن کامل

I-44: Color Doppler Imaging in Impotence

Sexual impotent is very common entity and define as inability to induce or maintaining penile erection during sexual intercourse. Studies reveals about 10% of men aged 40-70 years have complete, 17% have mild and 25% have moderate amount of erectile dysfunction. The sexual impotence has different etiology including psychogenic, neurogenic, arteriogenic and venogenic causes. Current studies reve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2009