A Scale Analysis Based Theoretical Force Balance Model for Critical Heat Flux „CHF... During Saturated Flow Boiling in Microchannels and Minichannels

نویسنده

  • Satish G. Kandlikar
چکیده

Accurate prediction of critical heat flux (CHF) in microchannels and minichannels is of great interest in estimating the safe operational limits of cooling systems employing flow boiling. Scale analysis is applied to identify the relevant forces leading to the CHF condition. Using these forces, a local parameter model is developed to predict the flow boiling CHF. The theoretical model is an extension of an earlier pool boiling CHF model and incorporates force balance among the evaporation momentum, surface tension, inertia, and viscous forces. Weber number, capillary number, and a new nondimensional group introduced earlier by Kandlikar (2004, “Heat Transfer Mechanisms During Flow Boiling in Microchannels,” ASME J. Heat Transfer, 126, pp. 8–16), K2, representing the ratio of evaporation momentum to surface tension forces, emerged as main groups in quantifying the narrow channel effects on CHF. The constants in the model were calculated from the available experimental data. The mean error with ten data sets is 19.7% with 76% data falling within 30% error band and 93% within 50% error band. The length to diameter ratio emerged as a parameter indicating a stepwise regime change. The success of the model indicates that flow boiling CHF can be modeled as a local phenomenon and the scale analysis is able to reveal important information regarding fundamental mechanisms leading to the CHF condition. DOI: 10.1115/1.4001124

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Study on Saturated Flow Boiling Critical Heat Flux in Microchannels

The saturated flow boiling critical heat flux in microchannels is investigated using water as the working fluid. The experimental test section has six parallel microchannels with each having a cross sectional area of 1054 × 157 micrometers. The mass flow rate, inlet temperature of the working fluids, and the electric current supplied to the resistive cartridge heater are controlled to provide q...

متن کامل

Critical Heat Flux Measurement and Model for Refrigerant-123 under Stabilized Flow Conditions in Microchannels

The present work is aimed toward understanding the effect of flow boiling stability on critical heat flux (CHF) with Refrigerant-123 (R-123) in microchannel passages. Experimental data and theoretical model to predict the CHF are the focus of this work. The experimental test section has six parallel microchannels with each having a cross sectional area of 1054 × 157 μm 2 . The effect of flow in...

متن کامل

The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux

One of the major industry problems is the flow boiling, where reaching to the critical heat flux (CHF) condition can lead to a temperature jump and damage of the systems. In the present study, the effects of a uniform change in tube diameter on subcooled flow boiling and CHF was numerically investigated. The Euler-Euler model was used to investigate the relationship between the two liquid and v...

متن کامل

On the Nature of Critical Heat Flux in Microchannels

The critical heat flux (CHF) limit is an important consideration in the design of most flow boiling systems. Before the use of microchannels under saturated flow boiling conditions becomes widely accepted in cooling of high-heat-flux devices, such as electronics and laser diodes, it is essential to have a clear understanding of the CHF mechanism. This must be coupled with an extensive database ...

متن کامل

Experimental Study on the Effect of Magnetic Field on Critical Heat Flux of Ferrofluid Flow Boiling in a Vertical Tube

In the present work, the critical heat flux measurements were performed for the subcooled flow boiling of pure water and magnetic nanofluids (i.e., water + 0.01 and 0.1 vol.% Fe‌‌3O4) in a vertical tube. The effect of applying an external magnetic field on the CHF variation was studied experimentally as well. The obtained results indicated that the subcooled flow boiling CHF in the vertical tub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009