Functional optical topography analysis using Statistical Parametric Mapping (SPM) methodology with and without physiological confounds
نویسندگان
چکیده
Functional optical topography (OT) measures the changes in oxygenated and deoxygenated hemoglobin (HbO(2), HHb) across multiple brain sites which occur in response to neuronal activation of the cerebral cortex. However, identification of areas of cortical activation is a complex task due to intrinsic physiological noise and systemic interference and careful statistical analysis is therefore required. A total of 10 young healthy adults were studied. The activation paradigm comprised of anagrams followed by finger tapping. 12 channels of the OT system were positioned over the frontal cortex and 12 channels over the motor cortex while the systemic physiology (mean blood pressure (MBP), heart rate (HR), scalp flux) was simultaneously monitored. Analysis was done using the functional Optical Signal Analysis (fOSA) software and Statistical Parametric Mapping (SPM), where we utilized two approaches: (i) using only HbO(2) as a regressor in the general linear model (GLM) and (ii) using all of the explanatory variables (HbO(2), MBP, HR and scalp flux) as regressors. Group analysis using SPM showed significant correlation in a large number of OT channels between HbO(2) and systemic regressors; however no differences in activation areas were seen between the two approaches.
منابع مشابه
Functional optical signal analysis: a software tool for near-infrared spectroscopy data processing incorporating statistical parametric mapping.
Optical topography (OT) relies on the near infrared spectroscopy (NIRS) technique to provide noninvasively a spatial map of functional brain activity. OT has advantages over conventional fMRI in terms of its simple approach to measuring the hemodynamic response, its ability to distinguish between changes in oxy- and deoxy-hemoglobin and the range of human participants that can be readily invest...
متن کاملComparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography
Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one ...
متن کاملAssessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)
Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...
متن کاملAccuracy and sensitivity of detection of activation foci in the brain via statistical parametric mapping: a study using a PET simulator.
Statistical parametric mapping (SPM) is currently the most widely used method for analysis of functional activation images. This paper reports a quantitative evaluation of the sensitivity and accuracy of SPM, using a realistic simulator of PET image formation, which accounted for the main physical processes involved in PET, including attenuation, scatter, randoms, Poisson noise, and limited det...
متن کاملMethodology of Optical Topography Measurements for Functional Brain Imaging and the Development and Implementation of Functional Optical Signal Analysis Software
Near-infrared spectroscopy (NIRS) has been used extensively in recent years as a noninvasive tool for investigating cerebral haemodynamics and oxygenation. The technique exploits the different optical absorption o f oxy-haemoglobin and deoxy-haemoglobin in the near infrared region to measure changes in their concentrations in tissue. By making multiple NIRS measurement simultaneously, optical t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 662 شماره
صفحات -
تاریخ انتشار 2010