Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

نویسندگان

  • A E Pekary
  • J M Hershman
چکیده

We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and Thyro-SHure TSH Diagnostic Kit (Nuclear Medical Laboratories). The correlation of all results obtained in the Hybritech assay with those of the two commercial RIAs exceeded 95%. Mean values for 100 euthyroid samples measured in the Hybritech assay were lower than for the other two methods. The separation between hyperthyroid and euthyroid patients was much clearer with the Hybritech assay than with the RIA methods. The Hybritech assay was far more sensitive than the Clinical Assays or the Nuclear Medical Laboratories assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ten commercial kits compared for assay of thyrotropin in the normal and thyrotoxic range.

I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly superior overall. Differences in calibration between kits were evident in a compar...

متن کامل

A SPECIFIC, SENSITIVE, AND ONE-STEP EXTRACTION RADIOIMMUNOASSAY OF TESTOSTERONE FOR CLINICAL DIAGNOSIS

Testosterone was measured using antibodies raised against testosterone II B-carboxymethyl ether bovine serum albmin (T-IIB-CME-BSA) and testosterone 3- O-carboxymethyl oxime-BSA as immunogen. The antibody produced in this study exhibits minimal cross reactivity with the structurally related steroids specially 5 dihydrotestosterone (5 DHD. This allows to ommit the clean up step and measure ...

متن کامل

Commercial assays for serum osteocalcin give clinically discordant results.

Serum samples from 9 healthy controls and from subjects with primary hyperparathyroidism (n = 5), Paget disease (n = 3), pregnancy (n = 5), glucocorticoid therapy (n = 5), postmenopausal osteoporosis (n = 10), and renal failure (n = 10) were used to assess the clinical agreement among eight commercially available assay kits for osteocalcin (OC). These kits differ in their assay configurations (...

متن کامل

Designing a Radioimmunometric Assay Kit for Prostate-Specific Antigen Measurement Using Polystyrene Tubes Coated By Immunochemical Method

ABSTRACT        Background and Objective: Prostate specific antigen (PSA) is considered as one of the most reliable biomarkers of cancer and other known prostate diseases. In the present study, solid phase sandwich immunoradiometric assay was used to measure the amount of PSA. In this type of measurement, a pair of anti-PSA antibodies on the solid phase and la...

متن کامل

Cross-reactivity of monomeric and dimeric biosynthetic human growth hormone in commercial immunoassays.

Commercial kits give different measurements for concentrations of growth hormone (GH, somatotropin) in serum. Most notably, a two-site monoclonal-antibody-based immunoradiometric assay (IRMA) from Hybritech routinely yields lower values than do conventional RIAs in which polyclonal antibodies are used. We used purified dimeric biosynthetic human GH as a model compound to investigate the specifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 1986