Comparison of outcomes with multifocal intraocular lenses: a meta-analysis

نویسندگان

  • Béatrice Cochener
  • Antoine Lafuma
  • Babak Khoshnood
  • Laurène Courouve
  • Gilles Berdeaux
چکیده

PURPOSE To compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature. METHODS All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected distance visual acuity, visual acuity, spectacle independence, and halos. Random effects meta-analyses were conducted to compare outcomes for the different IOL types. RESULTS Twenty papers were identified describing 11 monofocal IOLs and 35 multifocal IOLs (19 diffractive, including 12 ReSTOR(®), 14 refractive, and two accommodative) patient cohorts. Multifocal and monofocal uncorrected distance visual acuity was 0.165 (0.090-0.240) and 0.093 (0.088-0.098), respectively. Compared with monofocal IOLs, multifocal IOLs produced better uncorrected near visual acuity (0.470 [0.322-0.618] versus 0.141 [0.131-0.152]; P < 0.0001), resulting in higher spectacle independence (incidence rate ratio [IRR] 3.62 [2.90-4.52]; P < 0.0001). Compared with refractive multifocal IOLs, diffractive multifocal IOLs produced a similar uncorrected distance visual acuity (0.105 [0.098-0.111] versus 0.085 [0.029-0.140]; P ≤ 0.78, not significant) and better uncorrected near visual acuity (0.217 [0.118-0.317] versus 0.082 [0.067-0.098]; P < 0.0001) resulting in higher spectacle independence (IRR 1.75 [1.24-2.48]; P < 0.001). Compared with other multifocal IOLs, ReSTOR produced a better uncorrected distance visual acuity (0.067 [0.059-0.076] versus 0.093 [0.088-0.098]; P < 0.0001) and better uncorrected near visual acuity (0.064 [0.046-0.082] versus 0.141 [0.131-0.152]; P < 0.006), resulting in higher spectacle independence (IRR 2.06 [1.26-1.36]; P < 0.004). Halo incidence rates with different types of multifocal implants did not differ significantly. CONCLUSION Multifocal IOLs provide better uncorrected near visual acuity than monofocal IOLs, leading to less need for spectacles. Multifocal IOL design might play a role in postsurgical outcome, because better results were obtained with diffractive lenses. ReSTOR showed better uncorrected near visual acuity, uncorrected distance visual acuity, and higher spectacle independence rates compared with other multifocal IOLs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Through focus image quality of eyes implanted with monofocal and multifocal intraocular lenses

Intraocular lenses (lOLs) are commonly implanted in cataract surgery. Initially lOLs were mainly monofocal, but at present there are many multifocal lOLs available, which are being implanted. Multifocal lOLs have the potential advantage of reducing the dependence on spectacle correction for near vision after cataract surgery. Because the multifocal lOLs superimpose the near and far images on th...

متن کامل

Comparison of diffractive and refractive multifocal intraocular lenses in presbyopia treatment.

Multifocal intraocular lenses (MFIOL) enable good near and far vision after cataract surgery. Excellent results with cataract patients encouraged ophthalmologists to implant MFIOL after clear lens extraction (CLE). There are two types of MFIOL: diffractive and refractive. In our prospective study we compared clinical outcomes after CLE and bilateral implantation of diffractive (Tecnis Multifoca...

متن کامل

Analysis of the power profile of a new soft contact lens for myopia progression

1. Wagner S, Conrad F, Bakaraju RC, Fedtke C, Ehrmann K, Holden BA. Power profiles of single vision and multifocal soft contact lenses. Cont Lens Anterior Eye. 2014;38:2--14. 2. Plainis S, Atchison DA, Charman WN. Power profiles of multifocal contact lenses and their interpretation. Optom Vis Sci. 2013;90:1066--1077. 3. Joannes L, Hough T, Hutsebaut X, et al. The reproducibility of a new power ...

متن کامل

Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses

PURPOSE To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. METHODS The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patient...

متن کامل

Optical performance of monofocal versus multifocal intraocular lenses.

In their recent paper, Ortiz et al. studied the optical performance of monofocal and multifocal intraocular lenses (IOLs) in the human eye. Their main conclusion was that of the IOLs studied, the hybrid refractive–diffractive IOLwas the least affected by pupil diameter in terms of intraocular aberrations. This IOL type also showed a smaller increase in optical aberrations during pupil dilation....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011