The Effect of Conventional Instrument Transformer Transients on Numerical Relay Elements
نویسندگان
چکیده
Current and voltage transducers provide instrument level signals to protective relays. Protective relay accuracy and performance are directly related to the steady state and transient performance of the instrument transformers. Protective relays are designed to operate in a shorter time than the time period of the transient disturbance during a system fault. Large instrument transformer transient errors may delay or prevent relay operation. In this paper, we describe the effect of conventional instrument transformer transients on numerical relay elements and discuss numerical relay designs that cope with conventional instrument transformer transients. The elements we examine include distance, line differential, and breaker failure.
منابع مشابه
Elimination of Transformer Inrush Currents by Controlled Switching Part II - Application and Performance Considerations
Transformer inrush currents are highmagnitude, harmonic-rich currents generated when transformer cores are driven into saturation during energization. These currents have undesirable effects, including potential damage or loss-of-life to the transformer, protective relay misoperation, and reduced power quality on the system. Controlled transformer switching can potentially eliminate these trans...
متن کاملElimination of Transformer Inrush Currents by Controlled Switching—Part I: Theoretical Considerations
Transformer inrush currents are high-magnitude, harmonic-rich currents generated when transformer cores are driven into saturation during energization. These currents have undesirable effects, including potential damage or loss-of-life to the transformer, protective relay misoperation, and reduced power quality on the system. Controlled transformer switching can potentially eliminate these tran...
متن کاملDesigning of a New Transformer Ground Differential Relay Based on Probabilistic Neural Network
Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...
متن کاملA New Restricted Earth Fault Relay Based on Artificial Intelligence
The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...
متن کاملTransient Minimization Within Static Var Compensated Distribution Systems
VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...