Cardiac Image Analysis: Motion and Deformation
نویسندگان
چکیده
12.
منابع مشابه
Reducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملاصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملEstimation of 3D left ventricular deformation from echocardiography
The quantitative estimation of regional cardiac deformation from 3D image sequences has important clinical implications for the assessment of viability in the heart wall. Such estimates have so far been obtained almost exclusively from Magnetic Resonance (MR) images, specifically MR tagging. In this paper we describe a methodology for estimating cardiac deformations from 3D echocardiography (3D...
متن کاملMotion and deformation estimation from medical imagery by modeling sub-structure interaction and constraints
This paper presents a novel medical image registration algorithm that explicitly models the physical constraints imposed by objects or sub-structures of objects that have differing material composition and border each other, which is the case in most medical registration applications. Typical medical image registration algorithms ignore these constraints and therefore are not physically viable,...
متن کاملThe reproducibility of heart Deformation Analysis for the evaluation of global cardiac function
Background Analysis of global cardiac function is important for cardiovascular risk estimation but can be time-consuming. Using deformable image registration (DIR) algorithms, Heart Deformation Analysis (HDA) is a recently developed method for measuring cardiac function and motion on existing cardiac cine MR images. With a totally automatic workflow, HDA has the potential to be useful in clinic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000