High fidelity imaging using frequency sweep encoding
نویسنده
چکیده
Introduction: Recently Frydman et al proposed a novel mechanism for directly forming images in k space using frequency sweep encoding (1, 2). It relies on the quadratic dependence of magnetization phase on position. In combination with EPI-type readout, this method has found applications in single-shot spin-echo imaging of human and rat brains (3, 4). Its sequential excitation of magnetization may also be useful for novel image contrast generation and spectroscopic imaging. Fidelity of the images directly formed in k space is, however, severely degraded when compared with images formed using conventional phase encoding schemes with Fourier transform reconstruction. We show that fidelity of this type of images can be restored and also extend frequency sweep encoding to susceptibility-weighted imaging. Theory: Using a RF pulse with linear frequency sweep such as a Chirp pulse and a simultaneous encoding x gradient, magnetization is sequentially excited along the direction of the encoding gradient. The phase of the magnetization at the end of sequential excitation has a quadratic dependence on the x position of the magnetization: φ(x) = ax + bx +c [1] where the constants a, b, and c depends on frequency sweep and gradient parameters (1, 2). Upon reversing the polarity of the encoding gradient an echo is formed in k space with the following phase relationship: φ(k(t), x) = φ(x) –2πk(t)x [2] where k(t) represent k values as a linear function of time. Using Frydman’s argument, signals at a certain k(t) point arise mostly from spin packets at xk with xk determined by {dφ(k(t),x)/dx}x=xk = 0. At x ≠ xk, signals are largely dephased by the quadratic phase profile around xk. As a result, an image can be directly formed in k space with |S(t)| ~ ρ(xk) (1, 2). Unlike the sinc point spread function associated with conventional Fourier imaging signal dephasing in k space based on the quadratic phase profile (Eq. [2]) is incomplete. For the same number of pixels, the actual image resolution in the frequency sweep encoding direction is therefore significantly degraded, accompanied by significant geometrical distortions. In the reconstruction scheme proposed here the k space signal S(t) can be expressed in matrix form: S = FD [3] where S, F and D are matrices for k space signal (M × 1), Frydman encoding (M×N), and relaxation-weighted spin density (N×1), respectively, with M ≥ N. The elements of matrix F are given by a phasor smn = exp(i(φ(k(t),x)+ φ’(x)), where φ’(x) is an additional phase term to improve the conditioning of the Frydman encoding matrix F. Eq. [3] can be solved using least square: D = (FF)FS [4] where ‘†’ denotes conjugate transpose. For M = N, Eq.[3] can be factored into S = F’ΦD [5] where Φ is a diagonal matrix with element φnn~ exp(i2πa(n×FOV/N)) and F’ is the conventional Fourier matrix. Eq. [5] allows direct Fourier transform of the k space image to generate an image in the x space with a quadratic phase profile given by Φ. Methods and Results: Experiments were performed on a Bruker 11.7 Tesla scanner. SD rats (~200g) anesthetized using a mixture of 70% N2O, 30% O2, and 1.5% isoflurane were imaged using a 1-cm diameter surface coil for transmit and receive. The 2D version of the imaging sequence was shown in Fig. 1. A 8-ms chirp pulse of θ (nominal 90) degree with both edges rounded off was used for Frydman’s frequency sweep encoding. A 2-mm slice is selected using one 180 MAO pulse or two identical sech pulses. For 3D imaging, the 180 slice selective pulse(s) and slice gradient are replaced by phase encoding along the third dimension. To minimize geometrical distortion, the k space image was read out to allow equal TE for the sequentially excited magnetization (3, 4). FOV = 20 mm x 20 mm. Acquisition time = 8 ms. Matrix size = 512 x 512. TR = 1 s. No. of averages = 4. T2* delay time = 10 ms. For Fourier reconstruction, the k space data were directly Fourier transformed. A quadratic phase profile calculated from Bloch simulation of the frequency sweep pulse was used to correct the 2 order phase of the Fourier transformed image along the Frydman encoding dimension. After 2 order phase correction, the image data were inverse Fourier transformed in both dimensions. The central 32 x 32 k space data were apodized using a 2D Hanning filter and then Fourier transformed to generate a low-pass filtered 512 x 512 image. Finally, the original 2 order phase corrected image was demodulated using the phase of the low-pass filtered image (5). The results are shown in Fig. 2, top row. Using the same data, the images formed using only 1D Fourier transform along the conventional phase encoding direction are shown in Fig. 2 bottom row. The same 2 order phase correction was applied. Clearly, geometrical distortion and blurring along the frequency sweep encoding direction can be minimized using the procedure described in Theory (results using Eq. [4] are not shown). Conclusions: Combining Fourier transform and frequency sweep encoding allows formation of high fidelity images comparable to conventional images, thus giving impetus to develop new imaging methods utilizing Frydman’s sequential excitation and encoding with continuous frequency sweep. References: 1. Shrot et al, JMR 172:179 (2005) 2. Tal et al, JMR 182: 179 (2006) 3.Chamberlain et al, MRM 58:794 (2007) 4 Ben-Eliezer et al, MRI, in press (2009) 5. Noll et al, IEEE Trans Med Imag 10:154 (1991). Fig. 1
منابع مشابه
A new strategy for fast radiofrequency CW EPR imaging: direct detection with rapid scan and rotating gradients.
Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the s...
متن کاملFocal Sweep Imaging with Multi-focal Diffractive Optics
Depth-dependent defocus results in a limited depth-offield in consumer-level cameras. Computational imaging provides alternative solutions to resolve all-in-focus images with the assistance of designed optics and algorithms. In this work, we extend the concept of focal sweep from refractive optics to diffractive optics, where we fuse multiple focal powers onto one single element. In contrast to...
متن کاملImproved volumetric imaging in tomosynthesis using combined multiaxial sweeps
This study explores the volumetric reconstruction fidelity attainable using tomosynthesis with a kV imaging system which has a unique ability to rotate isocentrically and with multiple degrees of mechanical freedom. More specifically, we seek to investigate volumetric reconstructions by combining multiple limited-angle rotational image acquisition sweeps. By comparing these reconstructed images...
متن کاملPrecise control of broadband frequency chirps using optoelectronic feedback.
We demonstrate the generation of wideband frequency sweeps using a semiconductor laser in an optoelectronic feedback loop. The rate and shape of the optical frequency sweep is locked to and determined by the frequency of a reference electronic signal, leading to an agile, high coherence swept-frequency source for laser ranging and 3-D imaging applications. Using a reference signal of constant f...
متن کاملFrequency-modulation encoding in the primary auditory cortex of the awake owl monkey.
Many communication sounds, such as New World monkey twitter calls, contain frequency-modulated (FM) sweeps. To determine how this prominent vocalization element is represented in the auditory cortex we examined neural responses to logarithmic FM sweep stimuli in the primary auditory cortex (AI) of two awake owl monkeys. Using an implanted array of microelectrodes we quantitatively characterized...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009