A Low Conforming, Low Wear Solution in Fixed Bearing Total Knee Prostheses

نویسندگان

  • Alison L. Galvin
  • Louise M. Jennings
  • Lu Kang
  • Hannah McEwen
  • John Fisher
چکیده

Introduction: Ultra High Molecular Weight Polyethylene (PE) remains the primary bearing surface of choice in total knee replacements (TKR). Traditionally Archard’s Law is used to predict wear rates in hip and knee prostheses. This assumes that the volume of wear between two articulating surfaces is proportional to the applied load and sliding distance. However it has been shown that this is a simplification and that wear is controlled by levels of cross shear motion and contact stress [1,2]. Computational models and in vitro studies have shown that cross shear is important in predicting wear [3,4]. A reduction in cross shear in a mobile bearing (MB) knee in comparison to a fixed bearing (FB) knee results in a 4 fold reduction in wear [3]. However there is conflicting evidence as to the effect of contact stress on the wear of PE in FB knees. With historical PE, which was prone to oxidative degradation, reduced conformity and high stress levels were associated with delamination and structural fatigue. In contrast, by extrapolating pin on plate wear results, low conformity, small contact areas and higher stress would be indicative of lower wear [2]. The aim of this study was to compare the wear of FB knee replacements with curved and flat inserts and to test the hypothesis that the flat inserts which give higher contract stresses and smaller contact areas would lead to lower levels of surface wear. Materials and Methods: The wear of FB design TKRs was investigated using the PFC Sigma TKR (DePuy). These comprised of cobalt chrome femoral components which articulated against 10 mm thick curved or 6 mm thick flat UHMWPE inserts which were assembled by snap fit into cobalt chrome tibial trays. The tibial inserts were GUR 1020 UHMWPE which had been sterilized in foil pouches by gamma irradiation in a vacuum (GVF). The testing was performed on a six station knee simulator (Simulation Solutions, Manchester, UK) using femoral axial loading (max. 2600N) and flexion/extension (0 58°) profiles taken from ISO 14243 (2002). The motion profiles consisted of internal-external (IE) rotation ±5°, and anterior-posterior (AP) displacement, 0-10 mm for standard kinematics (Std) and 0-5mm for intermediate kinematics (Int). Tests were run under standard and intermediate kinematic conditions for a minimum of 3 million cycles. The simulator was run at 1 Hz and the lubricant used was 25% (v/v) newborn calf serum with 0.1% (w/v) sodium azide solution in deionised water. Wear of the tibial inserts was determined gravimetrically, using unloaded soak controls to compensate for moisture uptake. Volumetric wear was calculated from the weight loss of the inserts using a density of 0.934 mg/mm3. Statistical analysis was performed using One Way ANOVA. Results: The mean wear rates with 95% confidence limits for the curved and flat PE inserts are shown in Figure 1. The curved PE inserts had a mean wear rate of 15.93 ± 2.93 mm3 per million cycles (mm3/MC) under standard kinematics and 8.64 ± 3.35 mm3/MC with intermediate kinematics. In contrast the mean wear rate of the flat PE inserts under standard kinematics was 3.39 ± 0.68 mm3/MC and under intermediate kinematics was 3.07 ± 1.26 mm3/MC. The flat PE inserts had significantly (p<0.05) lower wear rates then the curved PE inserts under both kinematic conditions. The curved PE inserts under intermediate kinematics had a significantly (p<0.05) lower wear rate than the curved PE inserts under standard kinematics. The mean wear scars (percentage of total articulating area) for the curved PE inserts under standard kinematics was 34% ± 6% and for the flat PE inserts was 9% ± 1%. The flat PE inserts gave rise to a smaller contact area and therefore higher contact stress (77.94MPa for flat inserts, 31.41MPa for curved inserts). Figure 1. Mean Wear Rates ± 95% Confidence Limits Discussion: The wear rates for the flat PE inserts were significantly lower than for the curved PE inserts under both kinematics. The smaller wear scars seen on the flat PE inserts gave rise to higher contact stresses and lower wear. Previous studies of surface wear in hip simulators [5] have seen a decrease in wear rate with increasing contact stress. Additional studies carried out on multidirectional pin on plate wear simulators have also shown that an increase in contact stress gives a decrease in wear factor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses.

Polyethylene (PE) wear is the limiting factor for the longevity of a conventional total knee arthroplasty (TKA). Excessive wear leads to loosening and eventual implant failure. The aim of our in vitro study was to investigate wear of a PE tibial insert on a rotating platform as compared to the same insert fixed to the tibial baseplate and articulating with a similar femoral component. All tests...

متن کامل

Effect of Polyethylene Crosslinking and Bearing Design on Wear of Unicompartmental Arthroplasty.

Wear and polyethylene damage continue to be important factors affecting outcomes of unicompartmental knee arthroplasty. We compared two design rationales for unicompartmental arthroplasty: fully congruent mobile bearings; or moderately conforming fixed bearings using experimental and computational wear simulation. Experimental wear rates were 3.89 (±0.12) mg/million cycles for the highly crossl...

متن کامل

Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses.

Components from 73 failed knee replacements (TKRs) consisting of rotating-platform, mobile-bearing and fixed-bearing implants were examined to assess the patterns of wear. The patterns were divided into low-grade (burnishing, abrasion and cold flow) and high-grade (scratching, pitting/metal embedding and delamination) to assess the severity of the wear of polyethylene. The rotating-platform gro...

متن کامل

Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display-using a 3D optical scanner-wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee c...

متن کامل

Influence of conformity on the wear of total knee replacement: An experimental study

Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002