Evaluation of dermal irritation and skin sensitization due to vitacoxib

نویسندگان

  • Jianzhong Wang
  • Zhiyuan Li
  • Feifei Sun
  • Shusheng Tang
  • Suxia Zhang
  • Pengyyue Lv
  • Jing Li
  • Xingyuan Cao
چکیده

The prediction of side-effects is a key issue in the REACH initiative on chemicals in the preclinical testing of drugs. The dermal irritation and skin sensitization toxicity potential of a new molecule, vitacoxib, were invested in rabbits and guinea pigs in compliance with the Organization for Economic Cooperation and Development guideline. To assess dermal irritation, rabbits were dermally attached to vitacoxib for 72 h or repeated application. The results showed that no adverse reactions such as erythema and edema were observed throughout the test. In skin sensitization test, guinea pigs were sensitized to vitaoxib, positive and negative article for 24 h. No sensitization reaction was shown in the vitacoxib and negative group whereas severe sensitization was observed in the positive group. Based on these findings, vitacoxib does not cause dermal irritation and skin sensitization toxicity, and seems to be safe for animal use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TiO2 Nanoparticles as a Common Component of Sunscreens: An Experimental Study of Dermal/Ocular Safety Assessment

Background: The safety evaluations of sunscreens containing Titanium Dioxide-Nanoparticles (TiO2-NPs) were done by dermal exposure, acute dermal and eye irritation/corrosion, and skin sensitization according to the guideline for Organization for Economic Co-operation and Development (OECD). OBJECTIVES: The aim of our study was the evaluation of safety and toxicity of TiO2-NPs following acute su...

متن کامل

Assessment of phototoxicity, skin irritation, and sensitization potential of polystyrene and TiO2 nanoparticles

The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO2 nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also e...

متن کامل

First draft prepared

Explanation.................................................................................................. 256 Evaluation for acceptable daily intake......................................................... 256 Biochemical aspects............................................................................... 256 Absorption, distribution, and excretion ...........................................

متن کامل

Assessment of dermal exposure and histopathologic changes of different sized nano-silver in healthy adult rabbits

The human skin equivalent model (HSEM) is well known as an attractive alternative model for evaluation of dermal toxicity. However, only limited data are available on the usefulness of an HSEM for nanotoxicity testing. This study was designed to investigate cutaneous toxicity of polystyrene and TiO2 nanoparticles using cultured keratinocytes, an HSEM, and an animal model. In addition, we also e...

متن کامل

First draft prepared by A . Bartholomaeus Office of Chemical Safety Therapeutic Goods

Explanation.................................................................................................... 275 Evaluation for acceptable daily intakes ........................................................ 276 Biochemical aspects ................................................................................ 277 Absorption distribution and excretion ........................................

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017