3D/2D Registration of Mapping Catheter Images for Arrhythmia Interventional Assistance
نویسنده
چکیده
Radiofrequency (RF) catheter ablation has transformed treatment for tachyarrhythmias and has become first-line therapy for some tachycardias. The precise localization of the arrhythmogenic site and the positioning of the RF catheter over that site are problematic: they can impair the efficiency of the procedure and are time consuming (several hours). Electroanatomic mapping technologies are available that enable the display of the cardiac chambers and the relative position of ablation lesions. However, these are expensive and use custom-made catheters. The proposed methodology makes use of standard catheters and inexpensive technology in order to create a 3D volume of the heart chamber affected by the arrhythmia. Further, we propose a novel method that uses a priori 3D information of the mapping catheter in order to estimate the 3D locations of multiple electrodes across single view C-arm images. The monoplane algorithm is tested for feasibility on computer simulations and initial canine data.
منابع مشابه
Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.
Conventional fluoroscopy is the main imaging technology that allows for intracardiac device manipulation in a variety of interventional cardiovascular procedures. Besides the associated x-ray exposure for patients and staff, that technology only provides 2D orientations. Therefore, 3D mapping technologies have been introduced to facilitate spatial orientation within complex cardiac anatomies. E...
متن کاملA review of 3D/2D registration methods for image-guided interventions
Registration of pre- and intra-interventional data is one of the key technologies for image-guided radiation therapy, radiosurgery, minimally invasive surgery, endoscopy, and interventional radiology. In this paper, we survey those 3D/2D data registration methods that utilize 3D computer tomography or magnetic resonance images as the pre-interventional data and 2D X-ray projection images as the...
متن کاملRespiratory motion compensation by model-based catheter tracking during EP procedures
In many cases, radio-frequency catheter ablation of the pulmonary veins attached to the left atrium still involves fluoroscopic image guidance. Two-dimensional X-ray navigation may also take advantage of overlay images derived from static pre-operative 3D volumetric data to add anatomical details otherwise not visible under X-ray. Unfortunately, respiratory motion may impair the utility of stat...
متن کامل3D Augmented Fluoroscopy in Interventional Neuroradiology: Precision Assessment and First Evaluation on Clinical Cases
To improve the tool (guide wire and catheter) guidance in interventional radiology, a new approach is to project 3D X-ray Angiography (3DXA) information in real time onto a fluoroscopy image ("3D Augmented Fluoroscopy" 3D AF). Recovering the acquisition geometry is a crucial step for such augmented reality application. As 3DXA and fluoroscopy images are acquired on the same vascular C-arm, a ma...
متن کاملAn Efficient Registration Algorithm for Advanced Fusion of 2D/3D Angiographic Data
Computed tomography angiography (CTA) is often used for pre-interventional diagnosis and planning, whereas nowadays, mostly 2D angiograms are acquired for intra-interventional catheter guidance. Spatial information from pre-interventional scans is not transferred to the intervention yet since existing 2D-3D registration methods either require a good initial manual alignment or have rather long ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/0910.1844 شماره
صفحات -
تاریخ انتشار 2009