Remote plethysmographic imaging using ambient light.

نویسندگان

  • Wim Verkruysse
  • Lars O Svaasand
  • J Stuart Nelson
چکیده

Plethysmographic signals were measured remotely (> 1m) using ambient light and a simple consumer level digital camera in movie mode. Heart and respiration rates could be quantified up to several harmonics. Although the green channel featuring the strongest plethysmographic signal, corresponding to an absorption peak by (oxy-) hemoglobin, the red and blue channels also contained plethysmographic information. The results show that ambient light photo-plethysmography may be useful for medical purposes such as characterization of vascular skin lesions (e.g., port wine stains) and remote sensing of vital signs (e.g., heart and respiration rates) for triage or sports purposes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of ambient light in remote photoplethysmographic systems: comparison between a high-performance camera and a low-cost webcam.

Imaging photoplethysmography (PPG) is able to capture useful physiological data remotely from a wide range of anatomical locations. Recent imaging PPG studies have concentrated on two broad research directions involving either high-performance cameras and or webcam-based systems. However, little has been reported about the difference between these two techniques, particularly in terms of their ...

متن کامل

Remote Bridge Deflection Measurement Using an Advanced Video Deflectometer and Actively Illuminated LED Targets

An advanced video deflectometer using actively illuminated LED targets is proposed for remote, real-time measurement of bridge deflection. The system configuration, fundamental principles, and measuring procedures of the video deflectometer are first described. To address the challenge of remote and accurate deflection measurement of large engineering structures without being affected by ambien...

متن کامل

Night-time Remote Sensing of Fine Particulate Matter in the near Ground Atmosphere by Ground-based Hyperspectral Imaging

Spatiotemporal variations in attributes of particulate matter (PM) in ambient air are important estimates of environmental pollution and public health risks. In particularly, the exposure to fine PM, with count mean diameters of less than 4μm, has been associated with undesirable health effects. Therefore, methodologies that analyze the size profiles of fine PM in ambient air segments at ground...

متن کامل

Electro-Optical Design of Imaging Payload for a Remote Sensing Satellite

Remote sensing using small spacecraft arising from multi-objective economic activity problems is getting more and more developed. These satellites require very accurate pointing to specific locations of interest, with high reliability and small latency. The space borne imaging systems always attempted to achieve the highest ground resolution possible with the available technology at the given t...

متن کامل

Remote Measurement of Infant Emotion via Heart Rate Variability

Remote measurement of the blood volume pulse via imaging photoplethysmography (iPPG) using digital cameras and ambient light has great potential for healthcare and affective computing. This study introduces this iPPG method for detecting infant’s emotions pattern (discomfort and neutral) using video frames obtained from a low-cost webcam. Ten infants were obtained for heart rate(HR) and heart r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 26  شماره 

صفحات  -

تاریخ انتشار 2008