Comparison of premier CAMPY enzyme immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY tests with culture for laboratory diagnosis of Campylobacter enteric infections.

نویسندگان

  • Paul A Granato
  • Li Chen
  • Iris Holiday
  • Russell A Rawling
  • Susan M Novak-Weekley
  • Tammy Quinlan
  • Kimberlee A Musser
چکیده

Campylobacter enteritis is a food-borne or waterborne illness caused almost exclusively by Campylobacter jejuni and, to a lesser extent, by Campylobacter coli. These organisms produce indistinguishable clinical diseases and together represent the second most common cause of bacterial diarrhea in the United States and the leading cause of enteric infection throughout the world. The conventional approach to the laboratory diagnosis of Campylobacter enteritis is based on the recovery of the organism from a stool specimen, which requires the use of a specialized medium incubated at 42°C for several days in an artificially created microaerophilic environment. Recently, several commercially available enzyme immunoassays (EIAs) have been developed for the direct detection of C. jejuni and C. coli in stool specimens. This study compared conventional culture with three EIA methods, the Premier CAMPY EIA (Meridian Bioscience, Cincinnati, OH), the ProSpecT Campylobacter EIA (Remel, Lenexa, KS), and the ImmunoCard STAT! CAMPY test (Meridian Bioscience, Cincinnati, OH), for the detection of C. jejuni and C. coli in 485 patient stool samples. Discordant results were arbitrated by using an in-house, real-time PCR assay that was developed and validated by a public health reference laboratory. Following analyses of the discrepant specimens by PCR, the sensitivity and specificity of both the Premier CAMPY and ProSpecT Campylobacter EIAs were 99.3% and 98%, respectively, while the ImmunoCard STAT! CAMPY test had a sensitivity of 98.5% and a specificity of 98.2%. By use of the PCR test as the reference standard, culture detected 127 of 135 Campylobacter-positive stool specimens, yielding a sensitivity of 94.1%. These results showed that the three EIAs evaluated in this study provide a rapid and reliable alternative for the laboratory diagnosis of enteric infections with C. jejuni and C. coli and that conventional culture may no longer be recognized as the "gold standard" for diagnosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid detection of Campylobacter jejuni in stool specimens by an enzyme immunoassay and surveillance for Campylobacter upsaliensis in the greater Salt Lake City area.

The Alexon-Trend, Inc. (Ramsey, Minn.), ProSpecT Campylobacter microplate assay was compared with culture on a Campy-CVA plate (Remel, Lenexa, Kans.) and blood-free campylobacter agar with cefoperazone (20 microg/ml), amphotericin B (10 microg/ml), and teicoplanin (4 microg/ml) (CAT medium; Oxoid Limited, Hampshire, England) with 631 patient stool samples. The CAT medium was used to isolate Cam...

متن کامل

Evaluation of the positive predictive value of a rapid Immunochromatographic test to detect Campylobacter in stools

The recently developed rapid immunochromatographic tests (ICT) have the potential to provide a quick and easy diagnosis of Campylobacter enteritis in comparison to culture. In a previous study we found them sensitive but lacking in specificity. The aim of the present study was to focus on the problem of specificity and determine the positive predictive value (PPV) of a positive result of the Im...

متن کامل

Frequency of triggering bacteria in patients with reactive arthritis and undifferentiated oligoarthritis and the relative importance of the tests used for diagnosis.

OBJECTIVE Reactive arthritis (ReA) triggered by Chlamydia trachomatis or enteric bacteria such as yersinia, salmonella, Campylobacter jejuni, or shigella is an important differential diagnosis in patients presenting with the clinical picture of an undifferentiated oligoarthritis (UOA). This study was undertaken to evaluate the best diagnostic approach. PATIENTS AND METHODS 52 patients with Re...

متن کامل

Comparison of Enzyme Immunoassay, Immunochromatography, and RNA-Polyacrylamide-Gel Electrophoresis for Diagnosis of Rotavirus Infection in Children with Acute Gastroenteritis

Human rotavirus is a major etiologic agent for infantile diarrhea worldwide. It is responsible for up to 3.3 million deaths per year in children in developing countries. Various rapid and sensitive techniques have been developed to readily diagnose rotavirus gastroenteritis. In the present study, we compared the sensitivity and specificity of immunochromatography and RNA-polyacrylamide-gel elec...

متن کامل

Evaluation of different plate media for direct cultivation of Campylobacter species from live broilers.

Accurate identification and optimal culturing procedures for Campylobacter spp. from live broilers are needed for epidemiological studies. Because there is no standardized protocol, we designed and conducted studies to evaluate different selective media for the culturing and isolation of Campylobacter spp. from cecal and fecal samples obtained from battery-reared and commercial broilers. Five m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 48 11  شماره 

صفحات  -

تاریخ انتشار 2010