Off-axis compressed holographic microscopy in low-light conditions.
نویسندگان
چکیده
This Letter reports a demonstration of off-axis compressed holography in low-light level imaging conditions. An acquisition protocol relying on a single exposure of a randomly undersampled diffraction map of the optical field, recorded in the high heterodyne gain regime, is proposed. The image acquisition scheme is based on compressed sensing, a theory establishing that near-exact recovery of an unknown sparse signal is possible from a small number of nonstructured measurements. Image reconstruction is further enhanced by introducing an off-axis spatial support constraint to the image estimation algorithm. We report accurate experimental recovering of holographic images of a resolution target in low-light conditions with a frame exposure of 5 μs, scaling down measurements to 9% of random pixels within the array detector.
منابع مشابه
Compressed Sensing with off-axis frequency-shifting holography
This work reveals an experimental microscopy acquisition scheme successfully combining compressed sensing (CS) and digital holography in off-axis and frequency-shifting conditions. CS is a recent data acquisition theory involving signal reconstruction from randomly undersampled measurements, exploiting the fact that most images present some compact structure and redundancy. We propose a genuine...
متن کاملHolographic Microscopy for 3D Tracking of Bacteria
Understanding when, how, and if bacteria swim is key to understanding critical ecological and biological processes, from carbon cycling to infection. Imaging motility by traditional light microscopy is limited by focus depth, requiring cells to be constrained in z. Holographic microscopy offers an instantaneous 3D snapshot of a large sample volume, and is therefore ideal in principle for quanti...
متن کاملLow-Coherence, Common-Path, and Dynamic Holographic Microscopy and Nanoscopy Using Portable Systems
We present compact, portable and inexpensive interferometric systems for obtaining highly stable, easy-to-align holograms under low-coherence illumination, and use them for quantitative, label-free imaging of live cells and transparent elements with nano-scale thickness. OCIS codes: (090.1995) Digital holography; (090.2880) Holographic interferometry; (180.3170) Interference microscopy. Digital...
متن کاملSingle-shot Full-field reflection phase microscopy
We present a full-field reflection phase microscope that combines low-coherence interferometry and off-axis digital holographic microscopy (DHM). The reflection-based DHM provides highly sensitive and a single-shot imaging of cellular dynamics while the use of low coherence source provides a depth-selective measurement. The setup uniquely uses a diffraction grating in the reference arm to gener...
متن کاملOptimal spatial bandwidth capacity in multiplexed off-axis holography for rapid quantitative phase reconstruction and visualization
We present new methods for optimizing the spatial bandwidth capacity in off-axis holography using spatial multiplexing. We use optimal spatial multiplexing of off-axis holograms to fill the entire spatial frequency domain, including the space previously occupied by the intensity of the sample. Our approach enables spatial digital compression of eight offaxis holograms into a single real-valued ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 36 1 شماره
صفحات -
تاریخ انتشار 2011