Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

نویسندگان

  • Roberto Sasdelli
  • Cesar Higa Nomura
  • Ana Carolina Sandoval Macedo
  • Danilo Perussi Bianco
  • Fernando Uliana Kay
  • Gilberto Szarf
  • Gustavo Borges da Silva Teles
  • Hamilton Shoji
  • Pedro Vieira Santana Netto
  • Rodrigo Bastos Duarte Passos
  • Rodrigo Caruso Chate
  • Walther Yoshiharu Ishikawa
  • João Paulo Bacellar Costa Lima
  • Marcelo Assis Rocha
  • Vinícius Neves Marcos
  • Bruna Bonaventura Failla
  • Marcelo Buarque de Gusmão Funari
چکیده

Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the "as low as reasonable achievable" principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial

PURPOSE The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS). METHODS Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed u...

متن کامل

The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

OBJECTIVE To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). METHODS 50 patients (14 females, mean age 68 ± 9 years) who underwent CTCA (100 kV or 120 kV, 400-580 mA) within a single heartbeat were enrolled. Studies were reconstructed wi...

متن کامل

Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

OBJECTIVES This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA) following decennial screening guidelines. MATERIAL AND METHODS Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from pr...

متن کامل

Recent Update on Radiation Dose Assessment for the State-of-the-Art Coronary Computed Tomography Angiography Protocols

OBJECTIVES This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE). MATERIALS AND METHODS Prospectively ECG-triggered CCTA was performed using five commercially available CT scan...

متن کامل

Impact of iterative reconstruction vs. filtered back projection on image quality in 320-slice CT coronary angiography

Iterative reconstruction has been shown to reduce image noise compared with traditional filtered back projection with quantum denoising software (FBP/QDS+) in CT imaging but few comparisons have been made in the same patients without the influence of interindividual factors. The objective of this study was to investigate the impact of adaptive iterative dose reduction in 3-dimensional (AIDR 3D)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2013