PURPOSE The purpose of this study was to explore the correlation between the respiration-induced target motion and volume variation with the dosimetric variance on breast and organ at risk (OAR) during free breathing. METHODS AND MATERIALS After breast-conserving surgery, seventeen patients underwent respiration-synchronized 4DCT simulation scans during free breathing. Treatment planning was constructed using the end inspiration scan, then copied and applied to the other phases and the dose distribution was calculated separately to evaluate the dose-volume histograms (DVH) parameters for the planning target volume (PTV), ipsilateral lung and heart. RESULTS During free breathing, the treated breast motion vector was 2.09 ± 0.74 mm, and the volume variation was 3.05 ± 0.94%. There was no correlation between the breast volume and target/OAR dosimetric variation (|r| = 0.39 ~ 0.48). In the anteroposterior, superoinferior and vector directions, breast movement correlated well with the mean PTV dose, conformal index, and the lung volume receiving high dose (|r| = 0.651-0.975); in the superoinferior and vector directions, breast displacement only correlated with the heart volume receiving >5 Gy (V5) (r = -0.795, 0.687). The lung volume and the lung volume receiving high dose correlated reasonably well (r = 0.655 ~ 0.882), and a correlation only existed between heart volume and V5 (r = -0.701). CONCLUSION Target movement correlated well with the target/OAR dosimetric variation in certain directions, indicating that whole breast IMRT assisted by breathing control or respiratory-adapted gated treatment promotes the accuracy of dose delivery during radiotherapy. During free breathing, the effect of breast volume variation can be ignored in whole breast IMRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013