Toward optimized high-relaxivity MRI agents: thermodynamic selectivity of hydroxypyridonate/catecholate ligands.

نویسندگان

  • Valérie C Pierre
  • Marco Melchior
  • Dan M J Doble
  • Kenneth N Raymond
چکیده

The thermodynamic selectivity for Gd(3+) relative to Ca(2+), Zn(2+), and Fe(3+) of two ligands of potential interest as magnetic resonance imaging (MRI) contrast agents has been determined by NMR spectroscopy and potentiometric and spectrophotometric titration. The two hexadentate ligands TREN-6-Me-3,2-HOPO (H(3)L2) and TREN-bisHOPO-TAM-EA (H(4)L3) incorporate 2,3-dihydroxypyridonate and 2,3-dihydroxyterephthalamide moieties. They were chosen to span a range of basicity while maintaining a structural motif similar to that of the parent ligand, TREN-1-Me-3,2-HOPO (H(3)L1), in order to investigate the effect of the ligand basicity on its selectivity. The 1:1 stability constants (beta(110)) at 25 degrees C and 0.1 M KCl are as follows. L2: Gd(3+), 20.3; Ca(2+), 7.4; Zn(2+), 11.9; Fe(3+), 27.9. L3: Gd(3+), 24.3; Ca(2+), 5.2; Zn(2+), 14.6; Fe(3+), 35.1. At physiological pH, the selectivity of the ligand for Gd(3+) over Ca(2+) increases with the basicity of the ligand and decreases for Gd(3+) over Fe(3+). These trends are consistent with the relative acidities of the various metal ions;- more basic ligands favor harder metals with a higher charge-to-radius ratio. The stabilities of the Zn(2+) complexes do not correlate with basicity and are thought to be more influenced by geometric factors. The selectivities of these ligands are superior to those of the octadentate poly(aminocarboxylate) ligands that are currently used as MRI contrast agents in diagnostic medicine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward optimized high-relaxivity MRI agents: the effect of ligand basicity on the thermodynamic stability of hexadentate hydroxypyridonate/catecholate gadolinium(III) complexes.

The thermodynamic stabilities of the Gd(III) complexes of five hexadentate ligands, which incorporate the 2,3-dihydroxyterephthalamide and 2,3-hydroxypyridonate chelating moieties, have been determined by potentiometric and spectrophotometric titration. The ligands were chosen to span a range of basicities while maintaining a similar tripodal structural motif, facilitating a study of the effect...

متن کامل

Optimization of Expression and Purification Methods for the Study of Protein-Based Magnetic Resonance Imaging Contrast Agents

Magnetic Resonance Imaging instruments rely on a contrast agent to provide high-resolution images of tissues in vivo. However, current clinical contrast agents are hindered by low relaxivity and fast correlation time, necessitating high injection dosages. These concerns, among others, have driven the development of a class of protein-based contrast agents (ProCAs), by design of lanthanide bindi...

متن کامل

The effect of ligand scaffold size on the stability of tripodal hydroxypyridonate gadolinium complexes.

The variation of the size of the capping scaffold which connects the hydroxypyridonate (HOPO) binding units in a series of tripodal chelators for gadolinium (Gd) complexes has been investigated. A new analogue of TREN-1-Me-3,2-HOPO (1) (TREN = tri(ethylamine)amine) was synthesized: TREN-Gly-1-Me-3,2-HOPO (2) features a glycine spacer between the TREN cap and HOPO binding unit. TRPN-1-Me-3,2-HOP...

متن کامل

Gadolinium(III) 1,2-hydroxypyridonate-based complexes: toward MRI contrast agents of high relaxivity.

Prospective gadolinium(III) MRI contrast agent precursors [Gd-TREN-1,2-HOPO] (1) [TREN-1,2-HOPO = tris[(1-hydroxy-2-oxo-1,2-dihydropyridine-6-carboxamido)ethyl]amine] and [Gd-TREN-bis(Me-3,2-HOPO)-1,2-HOPO] (2) have been synthesized and characterized by relaxometric measurements. The water proton relaxivity values of 1 and 2 (20 MHz and 25 degrees C) are 9.5 and 9.3 mM(-)(1)s(-)(1), respectivel...

متن کامل

Design of Novel Protein-based MRI Contrast Agernets with High Relaxivity and Stability for Biomedical Imaging

Magnetic resonance imaging (MRI) is the leading imaging technique for disease diagnostics. MRI contrast agents facilitate MRI technique to obtain tissue-specific image with improved sensitivity and signal-to-noise ratio. However, the applications of current MRI contrast agents are hampered by their uncontrolled blood circulation time, low relaxivity, and low specificity. To address such need, I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Inorganic chemistry

دوره 43 26  شماره 

صفحات  -

تاریخ انتشار 2004