Complication With
نویسنده
چکیده
and Introduction Abstract Introduction: Intraosseous access (IO) is indicated if vascular access cannot be quickly established during resuscitation. Complication rates are estimated to be low, based on small patient series, model or cadaver studies, and case reports. However, user experience with IO use in real-life emergency situations might differ from the results in the controlled environment of model studies and small patient series. We performed a survey of IO use in real-life emergency situations to assess users' experiences of complications. Methods: An online questionnaire was sent to Scandinavian emergency physicians, anesthesiologists and pediatricians. Results: 1,802 clinical cases of IO use was reported by n=386 responders. Commonly reported complications with establishing IO access were patient discomfort/pain (7.1%), difficulties with penetration of periosteum with IO needle (10.3%), difficulties with aspiration of bone marrow (12.3%), and bended/broken needle (4.0%). When using an established IO access the reported complications were difficulties with injection fluid and drugs after IO insertion (7.4%), slow infusion (despite use of pressure bag) (8.8%), displacement after insertion (8.5%), and extravasation (3.7%). Compartment syndrome and osteomyelitis occurred in 0.6% and 0.4% of cases respectively. Conclusion: In users' recollection of real-life IO use, perceived complications were more frequent than usually reported from model studies. The perceived difficulties with using IO could affect the willingness of medical staff to use IO. Therefore, user experience should be addressed both in education of how to use, and research and development of IOs. Introduction Intraosseous access (IO) is indicated in critically ill patients if vascular access cannot be quickly established.[1] Complication rates with IO are estimated to be low, a notion that seems to come mainly from small patient series, model or cadaver studies, and case reports.[2–10] By convention, these studies often define "success rate" as insertion rate, i.e. the proportion of needles that penetrate the cortex. This success rate is usually high, 71–100%.[2–10] IO is a relatively rare occurrence in many settings, and healthcare staff might be inexperienced in the procedure or unfamiliar with the available IO device. Using IO in real-life situations could pose a different set of challenges (e.g., moving patient, high-stress situation, not much room to work around, many people involved in resuscitation) compared to the often controlled settings of small patient series, model or cadaver studies. Therefore, it is possible that the rate of experienced complications is much higher in real-life emergency situations than described in small patient series, Complication With Intraosseous Access Peter Hallas, MD, Mikkel Brabrand, MD, Lars Folkestad, MD Western J Emerg Med. 2013;14(5):440-443. http://www.medscape.com/viewarticle/813856_print 1 di 7 29/11/13 16:02 model or cadaver studies. Users' recollection of complications with using a medical device will influence their willingness to use it in the future. Thus, information on users' experience with complication rates in real-life use of IO could be used to identify issues for improvements in education and device design. For this purpose, we collected information on what Scandinavian emergency physicians, anesthesiologists and pediatricians experienced with real-life IO use. Methods We collected cases of users' experiences with cases of IO use by distributing a link to an online survey via e-mail to members of the Danish Society for Emergency Medicine (DASEM) (n=394 members). Responders were asked to recall all the cases where they had used IO in a clinical situation. Thus, the survey focused on the users' recollection of IO use. It did not involve review of patient charts, and it was not a prospective registration of cases. We used the survey software LimeSurvey (freely available at http://www.limesurvey.org). Additional responses were obtained by asking other Scandinavian emergency medicine, pediatric and anesthesiology societies and interest groups to distribute a link to the questionnaire to their members. These were the Danish Society for Anaesthesia and Critical Care, the Danish Paediatric Society, the Norwegian Society for Anaesthesiology, the Norwegian Society of Paediatricians, clinical staff at the Norwegian Air Ambulance, Norwegian Association on Trauma, Emergency and Disaster Medicine, the Swedish Society for Emergency Medicine, and the Swedish Society for Anaesthesia and Intensive Care. The survey was designed to collect detailed information on all clinical cases where the responders personally had used IO. We included responders in this analysis if they had real-life experience with IO (i.e., they had themselves placed or tried to place an IO). The responders were given detailed questions on successful and unsuccessful IO attempts, type of IO device used in each case, and complications or technical difficulties with the specific device. The questionnaire also included sections on training in IO and barriers to IO use in clinical settings; results on these aspects are published elsewhere.[11,12] We designed the survey so that no single patient could be identified from the data entered. Therefore, data on age groups, anatomical sites used and indication for IO placement were not available for all cases. The questionnaire had been tested by 5 doctors working in emergency care prior to distribution. None of them was involved in the research group. We used their feedback to improve the design of the survey. The survey did not fall under jurisdiction of the Danish Act on Processing of Personal Data and as it was not a clinical trial approval of an ethics committee was not relevant. We performed statistical analysis with Chi-test for trend and Fisher's Exact Test. Results We received 761 responses to the questionnaire; n=388 responders met the inclusion criteria. We excluded 2 of these due to gross inconsistencies in the answers. The response rate for DASEM members was 37.3%. Perceptions of IO Use in Scandinavia The 386 responders reported a total of 1,802 clinical cases of IO use. Information on age http://www.medscape.com/viewarticle/813856_print 2 di 7 29/11/13 16:02 of the patient was available for 1,719 cases. Of these, 774 (45.0%) were pediatric patients (under age 15) and 380 (49.1% of pediatric patients) were less than 2 years old. The ratio of needle use per patient was 1.17 for adults (15 years or older), 1.19 for children between 6 to 14 years (both inclusive), 1.18 for children between 2 and 5 years (both inclusive), and 1.14 for children under 2 years. (Chi square for trend did not detect a significant difference: p=0.98.) The indications for IO use were as follows: Cardiac arrest (28.4%; n=486), hemorrhage (23.4%; n=407), dehydration (16.7%, n=286), sepsis (13.4%, n=230), convulsions (2.7%; n= 46), poisoning (2.2%, n=37), and other clinical situations (12.8%, n=219). Information on indication for IO use was available for 1,711 cases (95.0%). IO had been placed in the tibia in 1,420 cases (89.7%), in the humerus in 54 cases (3.4%), in the iliac crest in 34 cases (2.1%), in the sternum in 27 cases (1.7%), in the femur in 20 cases (1.3%), and other sites in 28 cases (1.8%). Information on anatomical site was available for 1583 cases (87.8%). The IO-devices used were the following: EZ-IO in 861 cases (47.8%), Cook-Surfast in 418 cases (23.2%), B.I.G. in 255 cases (14.2%), and unspecified equipment in 268 cases (14.9%). Users' Recollection of Complications shows the overall frequency of reported complications and complication rates listed by device. In addition to Table, users reported "Miscellaneous complications" in n=36 cases (not specified). Table. Complication rate with intraosseous access (IO) reported by Scandinavian users listed by device. IO-equipment used All % EZ-IO B.I.G Cook Others p-value* Cases reported 1,802 100.0 861 255 418 268 Start complications Equipment difficult to assemble 36 2.0 4 21 5 6 < 0.0001 Difficult to identify correct anatomical site 57 3.2 28 17 5 7 0.0013 Bended or broken needle 72 4.0 11 17 20 24 < 0.0001 Patient discomfort/pain 128 7.1 73 13 20 22 0.0663 Difficult to penetrate the periosteum 186 10.3 18 56 51 61 < 0.0001 Difficult to aspirate bone marrow 221 12.3 92 51 38 40 < 0.0001 Complications in use Difficult to inject fluid and drugs 133 7.4 59 33 27 14 0.0026 http://www.medscape.com/viewarticle/813856_print 3 di 7 29/11/13 16:02 Slow infusion despite use of pressure bag 159 8.8 77 32 34 16 0.0610 Displacement after insertion 153 8.5 47 50 38 18 < 0.0001 Extravasation 66 3.7 25 12 17 12 0.4089 Late complications Compartment syndrome 10 0.6 6 1 1 2 0.796 Osteomyelitis 7 0.4 4 1 1 1 1.000 Skin infection 6 0.3 4 1 1 0 0.829 B.I.G, bone injection gun *The p-value is the probability of error in saying that at least one of the four categories is actually different from the others. Discussion In this study, IO users reported complications with real-life IO use from a multitude of settings, including prehospital, emergency departments (ED) and intensive care units. The rate of many of these complications will not be revealed in the controlled environment in simulation and cadaver studies for example, because they lack the difficulties with assembling equipment in extremely stressful situations and cannot be assessed for infection rates. Therefore, reports from a large number of cases of IO use are useful to get an estimate of complication rates in real-life situations (with the limitations of the study in mind, discussed below). More importantly, the users' recollection of difficulties with IO use could affect the willingness to use IO in future cases – even if the users don't recall every detail of the previous cases. Healthcare staff reported a wide range of difficulties with the use of IO. These difficulties might render the IO useless in an emergency situation. For example, the penetration through the cortex might have been successful, but the IO itself could be useless because of immediate dislocation. Thus, IO might not always be experienced as a straightforward procedure by healthcare staff when it is performed in real-life emergency situations. The study supports 2 common notions about IO. Firstly, that the rate of serious, late complications (i.e. compartment syndrome and ostemyolitis) is low. Indeed, the rate of 0.4–0.6% is remarkably close to the rates found in the 2 previous large-scale studies using this as a primary end-point. Secondly, that needle insertion rates per se can be tranferred from IO model or simulation studies to real-life situations: In about 90% of the reported cases in this study only 1 needle was used which corresponds to the needle insertions success rate often reported from model and cadaver studies The findings have implications for future education, design and research in IO usage. Doctors might be reluctant to use IO again if they remember earlier cases of IO use as difficult or as resulting in unexpected complications. Therefore, the difficulties reported by IO users should be considered when training healthcare staff in IO. It is the impression of the authors that many IO courses focus on the insertion step of the procedure. But perhaps educators to a wider extent should prepare healthcare staff for the most common difficulties in the later parts of the procedure as well and focus on measures to prevent http://www.medscape.com/viewarticle/813856_print 4 di 7 29/11/13 16:02 and deal with these issues. Furthermore, as can be seen from the , specific types of IO device designs seem to be prone to certain types of complications. Optimally, designers of IO devices should learn from these differences. In addition, the relatively high rate of difficulties after insertion should be kept in mind when doing research in IO, including simulation studies. Measuring IO success rate merely as "penetration through cortex" could miss clinically relevant complications. Table. Complication rate with intraosseous access (IO) reported by Scandinavian users listed by device. IO-equipment used All % EZ-IO B.I.G Cook Others p-value* Cases reported 1,802 100.0 861 255 418 268 Start complications Equipment difficult to assemble 36 2.0 4 21 5 6 < 0.0001 Difficult to identify correct anatomical site 57 3.2 28 17 5 7 0.0013 Bended or broken needle 72 4.0 11 17 20 24 < 0.0001 Patient discomfort/pain 128 7.1 73 13 20 22 0.0663 Difficult to penetrate the periosteum 186 10.3 18 56 51 61 < 0.0001 Difficult to aspirate bone marrow 221 12.3 92 51 38 40 < 0.0001 Complications in use Difficult to inject fluid and drugs 133 7.4 59 33 27 14 0.0026 Slow infusion despite use of pressure bag 159 8.8 77 32 34 16 0.0610 Displacement after insertion 153 8.5 47 50 38 18 < 0.0001 Extravasation 66 3.7 25 12 17 12 0.4089 Late complications Compartment syndrome 10 0.6 6 1 1 2 0.796 Osteomyelitis 7 0.4 4 1 1 1 1.000 Skin infection 6 0.3 4 1 1 0 0.829 B.I.G, bone injection gun *The p-value is the probability of error in saying that at least one of the four categories is actually different from the others. Limitations http://www.medscape.com/viewarticle/813856_print 5 di 7 29/11/13 16:02 The response rate for this questionnaire was 37% for DASEM members. This was estimated by comparing e-mail addresses from the survey with the membership register of DASEM. Some responders did not wish to state their e-mail address, so the response rate is a minimum estimate. For the rest of the societies a response rate could not be reliably estimated for reasons discussed elsewhere.[11] A low response rate could give a risk of selection bias, but a response rate of around 40% is actually considered average for e-mail surveys.[15] Because this study was founded on users' recollection of events rather than a review of patient databases or charts there was an obvious risk of recall bias. Thus, the complication rates reported by the users are not necessarily identical to the complication rates that would have been found in a prospective study or even in a retrospective study of patient charts. This was especially true for late complications, e.g., infections, since a doctor placing the IO in the prehospital setting or the ED often will have limited information on long-term complications. However, the data still accurately represent how users recall the cases. Conclusion In users' recollection of real-life IO use, the overall rate of complications was higher than usually reported from model and cadaver studies. The relatively high rate of difficulties after insertion should be addressed when the procedure is taught. Research on IO devices should focus on all stages of IO use. Focus only on "penetration through cortex" as a measure of IO success rate could miss clinically relevant complications.
منابع مشابه
Evaluation of Children with Complication of BCG Vaccination in North of Iran
Background: Although the efficacy of Bacillus Calmette-Guerin (BCG) vaccine in the prevention of tuberculosis has been noted consistently, the use of BCG vaccine is not without risk. In this study we aimed to evaluate immunologically, children with complication of BCG vaccination in North of Iran.Materials and Methods: This case-control study began in 30 Jan 2013 and was completed in 2 Jul 2015...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملCapsular Weakness around Breast Implant: A Non-Recognized Complication
Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...
متن کاملProposed Classification of Periampullary Diverticulum and its Role on Performing ERCP and Post ERCP Complication
Introduction: Duodenal diverticula are pouches of the mucosa, submucosa, and scattered muscle cells that extend through the intestinal wall. In this study, we aimed to classify the papilla position according to presence of PAD and evaluate the impact of papilla position on the success rate and post ERCP complication in the patients with PAD. Methods: This cross-sectional study was performed on...
متن کاملبررسی میزان بروز بیماران بستری شده به دنبال عوارض عمل جراحی در بیمارستان امام خمینی (ره) ساری، سال های 1386-1379
Background and purpose: Complication of surgery is one of the causes in further reference of inpatients to the hospital. Survey on complications is important resource in evaluation of rendered care to patient. Materials and methods: This is a cross sectional retrospective study. Medical records of patient who discharged with complication of surgery during 2000- 2007 from Imam hospital were...
متن کاملSevere muscle weakness during treatment with pegylated interferon alfa for chronic hepatitis C virus infection A rare complication
Background: Interferons (IFNs) are common therapeutics for several diseases such as viral hepatitis, multiple sclerosis and malignancy. A variety of autoimmune related side effects have been observed during IFN therapy. Rare cases of myopathy, polymyositis or dermatomyositis have been reported during therapy with high doses of IFN^5. Case Presentation: In this report, we describe a case with se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013