INFIX/EXFIX: Massive Open Pelvic Injuries and Review of the Literature
نویسندگان
چکیده
Introduction. Open pelvic fractures make up 2-5% of all pelvic ring injuries. Their mortality has been reported to be as high as 50%. During Operation Enduring Freedom protocols for massive open pelvic injuries lead to the survival of injuries once thought to be fatal. The INFIX is a subcutaneous anterior fixator for pelvic stabilization which is stronger than external fixation. The purpose of this paper is to describe the use of INFIX and modern algorithms for massive open pelvic injuries. Methods. An IRB approved retrospective review describes 4 cases in civilian practice with massive open pelvic injuries. We also review the modern literature on open pelvic injures. Discussion. Key components in the care of massive open pelvic injuries include hemorrhage control by clamping of the aorta or REBOA when necessary and fecal/urinary diversion. The INFIX can be used internally, as a partial INFIX partial EXFIX, or as an EXFIX. Its low profile allows for easy application of wound vacs and wound care and when subcutaneous avoids pin tract infections. Conclusion. Massive open pelvic injuries are a difficult problem. Following modern protocols can help prevent mortality.
منابع مشابه
Overlapped Pubic Symphysis; a Case Report and Review of the Literature
Overlapped pubic symphysis is a rare but serious pelvic injury. This study presents a case of overlapped dislocation of the pubic symphysis. He was managed by closed reduction under general anesthesia. The patient had urethral transsection.At the latest follow up, seven months post injury; he was able to walk well without any pelvic pain. However, his urologic problems were continued. We also r...
متن کاملThe functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation
Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...
متن کاملMidterm Radiographic and Functional Outcomes of the Anterior Subcutaneous Internal Pelvic Fixator (INFIX) for Pelvic Ring Injuries
OBJECTIVE To describe our experience using the anterior internal pelvic fixator (INFIX) for treating pelvic ring injuries. DESIGN Case Series. SETTING Level 1 Trauma Center. PATIENTS Eighty-three patients with pelvic ring injuries were treated with INFIX. Follow-up average was 35 months (range 12-80.33). INTERVENTION Surgical treatment of pelvic ring injuries included reduction, appropr...
متن کاملاداره پارگی وسیع پرینه در ترومای شدید لگن
Introduction: Significant perineal injuries and major pelvic fractures resulting from blunt trauma manifest a high-energy injury. Open pelvic fractures (with perineal injury) are associated with higher mortality rates of 40 to 60 %. Methods: This study was a review of patients with multiple traumas comprising of major pelvic fracture and severe perineal injuries (Shahid Kamyab hospital in Mash...
متن کاملMonoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw system...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016