A Study on Optimal Strategy in Relative Radiometric Calibration for Optical Sensors

نویسندگان

  • Kai Yu
  • Suhong Liu
  • Yongchao Zhao
چکیده

Based on the analysis of three main factors involved in the relative radiometric calibration for optical sensors, namely: the number of radiance level; the number of measurements at each level; and the radiance level grouping method, an optimal strategy is presented in this paper for relative radiometric calibration. First, the maximization to the possible extent of either the number of the radiance level or the number of measurements at each level can improve the precision of the calibration results, where the recommended number of measurements is no less than 20. Second, when the number of the radiance level is divisible by four, dividing all the levels evenly into four groups by intensity gradient order and conducting averages for each group could achieve calibration results with the highest precision, which is higher than the result of no grouping or any other grouping method with the mean square error being 2 2 M n / I T (where M n is the mean square error of noise in the calibration data, I is the number of the radiance level, and T is the number of measurements for each level. In this case, the first two factors had an equivalent effect and showed their strongest effect on the precision. Third, when the calibration data were not evenly divided, the number of measurements demonstrated a stronger effect than the number of the radiance level. These cognitions are helping to achieve more precise relative radiometric calibration of optical sensors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors

The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibratio...

متن کامل

An Overview of In-orbit Radiometric Calibration of Typical Satellite Sensors

This paper reviews the development of in-orbit radiometric calibration methods in the past 40 years. It summarizes the development of in-orbit radiometric calibration technology of typical satellite sensors in the visible/near-infrared bands and the thermal infrared band. Focuses on the visible/near-infrared bands radiometric calibration method including: Lamp calibration and solar radiationbas...

متن کامل

Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration

Radiometric cross-calibration between the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and the Terra-Moderate Resolution Imaging Spectroradiometer (MODIS) has been partially used to derive the ASTER radiometric calibration coefficient (RCC) curve as a function of date on visible to near-infrared bands. However, cross-calibration is not sufficiently accurate, since the ...

متن کامل

Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

LiDAR (Light Detection And Ranging) systems are capable of providing 3D positional and spectral information (in the utilized spectrum range) of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spect...

متن کامل

A Digital Sensor Simulator of the Pushbroom Offner Hyperspectral Imaging Spectrometer

Sensor simulators can be used in forecasting the imaging quality of a new hyperspectral imaging spectrometer, and generating simulated data for the development and validation of the data processing algorithms. This paper presents a novel digital sensor simulator for the pushbroom Offner hyperspectral imaging spectrometer, which is widely used in the hyperspectral remote sensing. Based on the im...