Rescue transoesophageal echocardiography for refractory haemodynamic instability during transvenous lead extraction.
نویسندگان
چکیده
AIMS The rising number of cardiovascular implantable electronic devices has led to a steep increase in transvenous lead extractions (TLEs). Procedure-related, haemodynamically significant adverse events are uncommon during TLE yet remain an inevitable risk. While the use of transoesophageal echocardiography (TEE) as a guide to clinical decision-making during refractory circulatory instability has been well established, the specific utility of rescue TEE during TLE has not been comprehensively studied. METHODS AND RESULTS Twenty-six patients who required emergent TEE to determine the aetiology of intractable haemodynamic instability during TLE were evaluated. Pericardial effusion requiring urgent pericardiocentesis and/or cardiac surgical intervention was diagnosed by TEE in 10 patients, and progressed to cardiac arrest in 4 patients. Haemorrhagic shock developed in two patients suffering from femoral vein laceration and right haemothorax, respectively. One additional patient developed acute respiratory compromise and right ventricular dysfunction diagnosed by TEE, which necessitated prolonged post-operative intubation and inotropic therapy. In 14 patients, TEE excluded life-threatening cardiovascular injuries and enabled the pursuit of continued medical management. Two patients with reassuring TEE findings underwent intra-operative placement of chest tubes for pneumothorax. All the 26 patients were discharged from the hospital. CONCLUSION While TLE is a relatively safe procedure, life-threatening cardiovascular injuries remain a rare risk. In this study, the use of rescue TEE ruled out significant cardiovascular injuries in the majority of patients. Furthermore, rescue TEE had a substantial impact on the efficiency of determining the aetiology of refractory haemodynamic instability during TLE and thereby facilitated the timely initiation of definitive intervention.
منابع مشابه
Impact of cytokine release on ventricular function after hepatic reperfusion: a prospective observational echocardiographic study with tissue Doppler imaging
BACKGROUND Postreperfusion syndrome and haemodynamic instability are predictors for poor outcome after liver transplantation. Cytokine release has been claimed to be responsible for postreperfusion syndrome. However, the underlying pathophysiologic mechanism is not clarified. The aim of this prospective observational study was to correlate cardiac performance (measured by transoesophageal echoc...
متن کاملAudit of anaesthetist-performed echocardiography on perioperative management decisions for non-cardiac surgery.
BACKGROUND Intraoperative transoesophageal echocardiography is increasingly used for guiding intraoperative management decisions during non-cardiac surgery. Transthoracic echocardiography (TTE) equipment and training is becoming more available to anaesthetists, and its point-of-care application may facilitate real-time haemodynamic management and preoperative screening. METHODS We conducted a...
متن کاملProbable right atrial thrombus immediately after recombinant activated factor VII administration.
We report the finding of a probable right atrial thrombus in a 33-yr-old male patient with severe head, chest, and abdominal trauma. Refractory coagulopathy and gross haemodynamic instability ensued, which was only partially controlled with massive blood product transfusion and high-dose inotropic support during laparotomy. Continuous transoesophageal echocardiography revealed a probable atrial...
متن کاملAccuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...
متن کاملThe details of an unusual “ghost” after transvenous lead extraction: Three-dimensional computed tomography analysis
Transvenous lead extraction (TLE) is performed to prevent deaths in patients with device infections. Intracardiac masses detected by echocardiography, i.e., "ghosts," are reported in 8% of patients after a TLE in retrospective studies and in 14% in prospective studies. We herein describe a case with unusual ghosts after a TLE. Three-dimensional computed tomography (3DCT) is useful for revealing...
متن کاملذخیره در منابع من