High rate ( up to 105 Hz / cm 2 ) , high position resolution ( 30 m m ) photosensitive RPCs

نویسنده

  • P. Fonte
چکیده

In many applications there is a need for high position resolution VUV and UV imagers. For these applications we have developed and successfully tested 1D and 2D VUV imaging detectors based on microgap RPCs. Two versions of these detectors were extensively tested: one filled with photosensitive vapours and the other one with the GaAs cathode coated by a 400 nm thick CsI layer. The main feature of these detectors is the high position resolution—30 mm in digital form. Additionally, it is spark-protected and can operate at high counting rates (up to 10Hz/cm). In this study the results in application for these detectors for spectroscopy are presented. r 2004 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performances of multi - gap timing RPCs for relativistic ions in the range Z = 1 - 6

We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (γβ =2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard 'off the shelf' 4-gap timing RPCs from the new HADES ToF wall. The resolution worsened to 100 ps for ∼ 1 kHz/cm 2 proton flux and for ∼ 100 Hz/cm 2 Carbon flux. The chambers were operate...

متن کامل

Development of high-rate timing RPCs

For many applications of RPCs to time-of-flight counters in heavy ion experiments the expansion to much higher values of the counting rate capability, so far limited to around 2 kHz/cm is of fundamental importance. To address this issue we developed single-gap timing RPCs with resistive electrodes made from a commercially available plastic material. Tests performed in photon beams yielded a tim...

متن کامل

First results on the angular resolution of the ARGO-YBJ detector

The ARGO-YBJ experiment at the YangBaJing Cosmic Ray Laboratory (Tibet, P.R. China, 4300 m a.s.l.), will be operating over the next years with the aim of studying cosmic rays, mainly cosmic γ-radiation, with an energy threshold of a few hundreds of GeV, by detecting small size air showers. The ARGO-YBJ apparatus will consist of a full coverage array of dimension ∼ 74× 78 m realized with a singl...

متن کامل

Beam test results of CMS RPCs at high eta region under high-radiation environment

The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz=cm. It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite ...

متن کامل

Status of the HADES RPC Project

In recent years, timing RPCs (Resistive Plate Chambers) [1] have emerged as a novel, cost-effective technology to achieve high timing resolutions σt≤100 ps as well as high granularities, which are required for high particle multiplicities. In order to cope with rates of Φ≤700 Hz/cm (expected for Au+Au collisions), the HADES detector is being upgraded. As a part of the upgrade project, an RPCbas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004