Accurate Measurement of Small Execution Times - Getting Around Measurement Errors

نویسندگان

  • Carlos Moreno
  • Sebastian Fischmeister
چکیده

Engineers and researchers often require accurate measurements of small execution times or duration of events in a program. Errors in the measurement facility can introduce important challenges, especially when measuring small intervals. Mitigating approaches commonly used exhibit several issues; in particular, they only reduce the effect of the error, and never eliminate it. In this letter, we propose a technique to effectively eliminate measurement errors and obtain a robust statistical estimate of execution time or duration of events in a program. The technique is simple to implement, yet it entirely eliminates the systematic (non-random) component of the measurement error, as opposed to simply reduce it. Experimental results confirm the effectiveness of the proposed method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate Measurement of Small Execution Times –Getting Around Measurement Errors (Extended Technical Report)

Engineers and researchers often require accurate measurements of small execution times or duration of events in a program. Errors in the measurement facility can introduce important challenges, especially when measuring small intervals. Mitigating approaches commonly used exhibit several issues; in particular, they only reduce the effect of the error, and never eliminate it. In this technical r...

متن کامل

Quantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients

Background: The success of radiation therapy depends on accurate dose delivery to the target. Diode in vivo measurement of entrance and exit dose is a valuable quality assurance (QA) tool to ensure accurate dose delivery.  Materials and Methods: This study was performed at BINO Cancer Hospital, Bahawalpur. Entrance and exit dose measurements were done with p-type diode for various types of canc...

متن کامل

The Effect of Measurement Errors on the Performance of Variable Sample Size and Sampling Interval Control Chart

The effect of measurement errors on adaptive and non-adaptive control charts has been occasionally considered by researchers throughout the years. However, that effect on the variable sample size and sampling interval (VSSI) control charts has not so far been investigated. In this paper, we evaluate the effect of measurement errors on the VSSI control charts. After a model development, the effe...

متن کامل

Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry

Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...

متن کامل

Platform Independent Timing of Java Virtual Machine Bytecode Instructions

The accurate measurement of the execution time of Java bytecode is one factor that is important in order to estimate the total execution time of a Java application running on a Java Virtual Machine. In this paper we document the difficulties and solutions for the accurate timing of Java bytecode. We also identify trends across the execution times recorded for all imperative Java bytecodes. Thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Embedded Systems Letters

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017