Versatile semiautomated sample processor and gamma counter to increase radioimmunoassay efficiency.
نویسندگان
چکیده
We describe a semiautomated batch-assay system designed to increase the speed and ease of performing radioimmunoassays while maintaining good accuracy and precision. The main components are a programmable pipetting unit (sample processor) and a gamma counter capable of simultaneously counting radioactivity in 12 samples. The processor uses prearranged sets of as many as 24 disposable pipette tips, which eliminates carryover between samples, and features a horizontal shaker and magnetic stirrer; 50 different assay protocols can be selected. Batches of tubes are easily transferred from the sample processor to the incubator and centrifuge. The gamma counter is controlled by a microprocessor, which is also used for data processing. Because the system is based on discrete rather than continuous-flow analysis and because of the ease with which consecutive samples can be processed, more than one operation and several different assays can be accommodated simultaneously, which saves time considerably.
منابع مشابه
Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization
BACKGROUND Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable (68)Ge/...
متن کاملCounting Non-Aqueous Samples in the TopCount® Microplate Scintillation and Luminescence
The microplate format has become a standard for many biological assays such as high throughput screening for drug discovery and radioimmunoassays. Productivity with these high volume procedures has been limited by the amount of sample handling required and low sample counting throughput. Now, however, microplate assays can be efficiently counted in microplates with the Packard TopCount Micropla...
متن کاملInfrared Counter-Countermeasure Efficient Techniques using Neural Network, Fuzzy System and Kalman Filter
This paper presents design and implementation of three new Infrared Counter-Countermeasure (IRCCM) efficient methods using Neural Network (NN), Fuzzy System (FS), and Kalman Filter (KF). The proposed algorithms estimate tracking error or correction signal when jamming occurs. An experimental test setup is designed and implemented for performance evaluation of the proposed methods. The methods v...
متن کاملStudy on effect of detector type in estimating buildup factor of gamma-rays by monte carlo simulation based on variance reduction
This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...
متن کاملA faster radioimmunoassay of progesterone in plasma, with use of polyethylene glycol as precipitant.
We report a reliable radioimmunoassay for plasma progesterone in which polyethylene glycol ("Carbowax 6000") is used to separate antibody-bound and free hormone. Initially, progesterone is concentrated by putting the sample through a column of LH-20 Sephadex. Procedural losses in each sample are not monitored. We compared the reliability and practicality of this method with that of another meth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 28 4 Pt 1 شماره
صفحات -
تاریخ انتشار 1982