A microfluidic device with integrated fluorimetric detection for flow injection analysis.

نویسندگان

  • Alexandre Fonseca
  • Ivo M Raimundo
  • Jarbas J R Rohwedder
  • Renato S Lima
  • Mário C Ugulino Araújo
چکیده

This work describes the development of flow analysis microsystems with integrated fluorimetric detection cells. Channels (width of 300-540 microm and depth of 200-590 microm) were manufactured by deep-UV lithography in urethane-acrylate (UA) resin. Plastic optical fibers (diameter of 250 microm) were coupled to a 2.0-mm-long detection channel in order to guide the excitation radiation from an LED (470 nm) and collect the emitted radiation at a right angle towards a photomultiplier. A single-line miniaturized system, with a total internal volume of 10.4 microL, was evaluated by means of standard fluorescein solutions (0.53-2.66 micromol L(-1), pH 8.5). The analytical signals presented a linear relationship in the concentration range studied, with a relative standard deviation of 1.9% (n = 5), providing a detection limit of 0.37 micromol L(-1) and an analytical frequency of 60 samples/h, using a flow rate of 60 microL min(-1). Optical microscopy images and videos acquired in real time for the hydrodynamic injection of 130 and 320 nL of sample solutions indicated the good performance of the proposed sampling strategy. Another microsystem with a total internal volume of 38 microL was developed, incorporating a confluence point for two solutions. This device was applied to the determination of the total concentration of Ca(2+) and Mg(2+) in commercial mineral waters using the calcein method. Microscopy images and videos demonstrated the mixing efficiency of the solutions in the microchannels. A linear relationship was observed for the analytical signal in the Ca(2+) concentration range from 25 to 125 micromol L(-1), with relative standard deviations of 3.5%. The analysis of mineral waters with the proposed system provided results that did not differ significantly from those obtained by the EDTA titration method at a confidence level of 95%. These results demonstrate the viability of developing micro flow injection systems with an integrated fluorimetric detection cell.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study of Droplet Generation Process in a Microfluidic Flow Focusing

Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...

متن کامل

Microfluidic chip-based valveless flow injection analysis system with gravity-driven flows.

In this work, a microfluidic chip-based valveless flow injection analysis (FIA) system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. Automated sample injection in the 0.3-6.4 nL range under gated injection mode was achieved by controlling the vertical position of the waste reservoir fixed on a moving platform and the residence time of the reser...

متن کامل

Toward complete miniaturisation of flow injection analysis systems: microfluidic enhancement of chemiluminescent detection.

Conventional flow injection systems for aquatic environmental analysis typically comprise large laboratory benchscale equipment, which place considerable constraints for portable field use. Here, we demonstrate the use of an integrated acoustically driven microfluidic mixing scheme to enhance detection of a chemiluminescent species tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate-a common ...

متن کامل

An integrated, multiparametric flow cytometry chip using "microfluidic drifting" based three-dimensional hydrodynamic focusing.

In this work, we demonstrate an integrated, single-layer, miniature flow cytometry device that is capable of multi-parametric particle analysis. The device integrates both particle focusing and detection components on-chip, including a "microfluidic drifting" based three-dimensional (3D) hydrodynamic focusing component and a series of optical fibers integrated into the microfluidic architecture...

متن کامل

Integrated label-free silicon nanowire sensor arrays for (bio)chemical analysis.

We present a label-free (bio)chemical analysis platform that uses all-electrical silicon nanowire sensor arrays integrated with a small volume microfluidic flow-cell for real-time (bio)chemical analysis and detection. The integrated sensing platform contains an automated multi-sample injection system that eliminates erroneous sensor responses from sample switching due to flow rate fluctuations ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 396 2  شماره 

صفحات  -

تاریخ انتشار 2010