Fatal upper gastrointestinal bleeding caused by a metal biliary stent despite stent shortening with APC.

نویسندگان

  • S Dokas
  • V Kotsis
  • G Milionis
  • G Lazaraki
  • M Sion
چکیده

temesis and melena. He had received an uncovered nitinol self−expanding metal stent (SEMS) 2 months previously for in− operable obstructive hilar cholangiocar− cinoma. Upper endoscopy revealed a normal esophagus, stomach, and duodenal bulb. At the duodenal wall opposite the papilla, a large ulceration with hematin spot (l" Fig. 1) had formed as a result of SEMS impaction. We decided to shorten the stent with argon plasma coagulation (APC). For this procedure we used a duo− denoscope and an ERBE generator (APC settings: power 80 W, flow rate 1.8 l/min− ute). The section was done circumferen− tially 1 cm from the papilla (l" Fig. 2), and the stent was shortened by 1.5 cm (l" Fig. 3). During his hospitalization the patient was making progress and his he− matocrit was stable. He was discharged 4 days later. He presented again to our hospital the next day with massive hematemesis and melena. At admission he was already in severe oligemic shock and succumbed shortly afterwards. Ulceration is caused by continuous me− chanical irritation of the mucosa opposite the distal end of the stent. Distal migra− tion or malpositioning are the causes of this complication. Furthermore, mucosal ulceration may be promoted by the sharp edges of metal stents [1]. To date, several cases of ulceration and bleeding caused by biliary SEMS have been reported [1± 3]. In most cases, bleeding was self−limit− ing. When indicated, endoscopic hemo− stasis successfully arrested the bleeding. APC is reported to be a safe, effective, and easy way to reduce stent length [2± 4]. Shortening of the stent, with or with− out endoscopic hemostasis, was enough to permanently correct the complication in the published cases. Fatal bleeding from SEMS−induced ulceration has never been reported, let alone after endoscopic trimming with APC. Metal stents are a valuable means of re− storing the continuity of the biliary tract. Choosing the correct size and accurate positioning are key factors to reducing complications. Furthermore, metal stents with rounded edges could reduce the risk of ulceration. Finally, longer hospitaliza− tion may be advisable when treating SEMS−induced bleeding ulcers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Thermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model

Constitutive law for shape-memory alloys subjected to multi-axial loading, which is based on a semi-micromechanical integrated multi-plane model capable of internal mechanism observations, is generally not available in the literature. The presented numerical results show significant variations in the mechanical response along the multi loading axes. These are attributed to changes in the marten...

متن کامل

Post-biliary sphincterotomy bleeding despite covered metallic stent deployment

OBJECTIVES Several endoscopic techniques have been proposed for the management of post-sphincterotomy bleeding. Lately, self-expandable metal stents deployment has gained popularity especially as a rescue therapy when other endoscopic techniques fail. METHODS-RESULTS We report the case report of a massive post-sphincterotomy bleeding in a patient with a self-expandable metal stent in the bili...

متن کامل

A novel endoscopic treatment of hemosuccus pancreaticus: a stent tree tamponade.

CONTEXT Hemosuccus pancreaticus is a rare cause of intermittent upper gastrointestinal bleeding, commonly caused by aneurysmal rupture. Prompt diagnosis and treatment is required. The standard treatment involves embolization via interventional radiology or a surgical approach. CASE REPORT We report a novel endoscopic approach to hemosuccus pancreaticus with a successful tamponade via pancreat...

متن کامل

Bleeding Risk of Stent Removal After EUS-Guided Cystgastrostomy and Metal Stent Placement for Drainage of a Pancreatic Fluid Collection

Endoscopists are keenly aware of bleeding risks during and immediately after cystgastrostomy and reduce this risk by endoscopic ultrasound guidance to avoid manipulation near major vessels. Bleeding risk associated with cystgastrostomy stent removal after resolution of a pancreatic fluid collection, however, is less evident. We present our experience with bleeding during cystgastrostomy stent r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Endoscopy

دوره 40 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2008