Investigation of dairy cattle ease of movement on new methyl methacrylate resin aggregate floorings.
نویسندگان
چکیده
Freestall dairy farms commonly present issues with cattle slips and falls caused by smooth flooring and manure slurry. This study examined the effect of 4 new methyl methacrylate (MMA) resin aggregate flooring types (1-4) compared with rubber (positive) and concrete (negative control) on dairy cow (n=18) ease of movement when walking on straight and right-angled corridors. Our hypothesis was that cow ease of movement when walking on the MMA surfaces would be better than when walking on traction milled concrete, and at least as good as when walking on rubber. Cattle ease of movement was measured using kinematics, accelerometers, and visual observation of gait and associated behaviors. Stride length, swing time, stance time, and hoof height were obtained from kinematic evaluation. Acceleration and asymmetry of variance were measured with accelerometers. Locomotion score and behaviors associated with lameness, such as arch back, head bob, tracking up, step asymmetry, and reluctance to bear weight were visually observed. Stride length, swing time, stance time, and the number of steps taken were the only variables affected by flooring type. Differences between flooring types for these variables were tested using a generalized linear mixed model with cow as a random effect, week as a random block factor, and flooring type as a fixed effect. Multiple comparisons with a Scheffé adjustment were done to analyze differences among flooring types. Stride length was 0.14 m longer (better) on rubber when compared with concrete, and 0.11 and 0.17 m shorter on MMA 1 and 2 compared with rubber. On MMA 3 and 4, stride length did not differ from either rubber or concrete. Swing time was 0.04 s shorter (worse) on MMA 1 than on rubber, but did not differ from any other flooring. Stance time was 0.18 s longer (worse) on MMA 2 when compared with rubber, but it did not differ from any other treatment. The number of steps was higher on MMA 4 compared with rubber (4.57 vs. 3.95 steps), but did not differ from any other treatment. Of all the MMA floors tested, MMA 3 was the only one that was consistently as good as rubber (positive control). All 4 MMA floors never differed from concrete (negative control) in any of the ease of movement variables measured. These results suggest that MMA 3 may improve cow ease of movement, compared with the other MMA floors, but more research is required to confirm these findings.
منابع مشابه
Denture base polymers, poly methyl methacrylate improved using free radical copolymerization
Poly methyl methacrylate (PMMA) is the most common material used in Prosthodontics. Several studies indicate a breakdown of the number of very high resin bases after 2 to 3 years to avoid breaking bass and several attempts have been made, such as altering the chemical structure of resin by adding causes cross linking or copolymerization. The innovative method for improving the physical properti...
متن کاملInvestigation of Operational Parameters on the Photocatalytic Activity of a New Type of Poly(methyl methacrylate)/Ionic Liquid-TiO2 Nanocomposite
This research work intended to study some important operational parameters on the photocatalytic activity of a new type of poly(methyl methacrylate) (PMMA)/IL-TiO2 nanocomposite, prepared by microemulsion method. For the first step, it is confirmed that the prepared nanocomposite has a significant effect on photodecomposition of the Trypan Blue (TB), as an anionic hydrophilic azo...
متن کاملInvestigation of Differences in Biochemical and Mineral Composition of Urine between Pregnant and Non-Pregnant Crossbred Dairy Cattle
Dairy farmers have been longing for simple and economical methods of early pregnancy diagnosis. Urine based biochemical and mineral assays could be one of those methods, owing to the ease of sample collection and relatively simple and economical assays involved. However, basic information on changes in urinary composition during early pregnancy in cattle is lacking. This study was designed to e...
متن کاملDesign and Production of Two-Piece Thyroid-Neck Phantom by the Concurrent Use of Epoxy Resin and Poly(Methyl Methacrylate) Soft Tissue Equivalent Materials
The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass attenuation coefficients of the epoxy resin and the plexiglass compounds were obtained from simulation (NIST XCOM 3.1) and measurements (practical dosimetry) and compared to th...
متن کاملThe effect of SiO2 nano-filler addition into heat-cured poly methyl methacrylate on three-point flexural strength
Background and Aims: Poly methyl methacrylate (PMMA) is still the most commonly used material in prosthetic dentistry. However, there are problems with the mechanical properties of this type of material including low flexural strength. Addition of nanoparticles into the polymer is one way to improve the mechanical properties of acrylic resin. In the present study, the effect of silicon dioxide ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of dairy science
دوره 99 10 شماره
صفحات -
تاریخ انتشار 2016