Real-time optical motion correction for diffusion tensor imaging.

نویسندگان

  • Murat Aksoy
  • Christoph Forman
  • Matus Straka
  • Stefan Skare
  • Samantha Holdsworth
  • Joachim Hornegger
  • Roland Bammer
چکیده

Head motion is a fundamental problem in brain MRI. The problem is further compounded in diffusion tensor imaging because of long acquisition times, and the sensitivity of the tensor computation to even small misregistration. To combat motion artifacts in diffusion tensor imaging, a novel real-time prospective motion correction method was introduced using an in-bore monovision system. The system consists of a camera mounted on the head coil and a self-encoded checkerboard marker that is attached to the patient's forehead. Our experiments showed that optical prospective motion correction is more effective at removing motion artifacts compared to image-based retrospective motion correction. Statistical analysis revealed a significant improvement in similarity between diffusion data acquired at different time points when prospective correction was used compared to retrospective correction (P<0.001).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volumetric navigators for real-time motion correction in diffusion tensor imaging.

Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the con...

متن کامل

Comparison of Image-Based Retrospective and Optical Prospective Motion Correction for Diffusion Tensor Imaging

INTRODUCTION Correction of rigid head motion correction is important in diffusion tensor imaging because of the long acquisition times. Rigid head correction can be carried out either retrospectively prospectively. In this study, we compared the effectiveness of these two approaches in correcting motion artifacts in DTI. Retrospective correction was based on MR-based navigator data (1-3), whils...

متن کامل

Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging

Thesis: Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging Author‟s Name: Alkathafi A. Alhamud Date: 10-02-2012 Diffusion Tensor Imaging (DTI) is used to detect microstructural changes in the human brain. Although echo planar imaging (EPI) has been implemented in diffusion pulse sequences to minimize the effect of subject motion, motion artifacts...

متن کامل

MR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI

Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging usin...

متن کامل

Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

A fat-saturated twice-refocused spin echo sequence was implemented on a GE Signa 1.5-T whole-body system for diffusion-weighted imaging. Data were acquired using an analytically designed interleaved variable-density (VD) spiral readout trajectory. This flexible design algorithm allowed real-time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k-space. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2011