The influence of heavy water on boron requirements for neutron capture therapy.
نویسندگان
چکیده
Neutron penetration in tissue is a major limitation of thermal NCT, as such much work has centered upon the epithermal neutron beam in an effort to improve this situation. Further gains in neutron flux penetration, and thus therapeutic ratios, are possible if natural water is replaced with heavy water prior to therapy. Applying MCNP to a heterogeneous ellipsoidal skull/brain model, advantage depth and therapeutic depth parameters are studied as a function of heavy water replacement for a range of tumor to blood boron ratios. Both thermal (0.025 eV) and epithermal (2-7 keV) ideal neutron beams are analyzed. Using 10B ratios in the range of documented human uptake, the thermal advantage depth improved by approximately 0.7 cm for 20% D2O replacement, however, the therapeutic depth increased by less than half this value. For the epithermal beam, both the advantage depth and the therapeutic depth increased by over 1 cm. Effects of heavy water replacement on 10B requirements to therapeutically treat the midline of the brain are also evaluated.
منابع مشابه
10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy
Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation stud...
متن کاملInvestigation the potential of Boron neutron capture therapy (BNCT) to treat the lung cancer
Introduction: Boron neutron capture therapy (BNCT) is recommended to treat the glioblastoma tumor. It is well known that neuron beams are more effective treatment than photon beams to treat hypoxia tumors due to interaction of neutron with nucleus and production of heavy particles such as 7Li and alpha particle. In this study to evaluate the suitability of BNCT for treating of ...
متن کاملAn investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملPlant-Based Calcium Fructoborate as Boron-Carrying Nanoparticles for Neutron Cancer Therapy
Boron neutron capture therapy (BNCT) is an effective clinical method in cancer treatment based on fission reactions and nuclear capturing. In this method, use of the best boron-containing agents for boron therapy and boron delivery agent for transfer to the infectious site are the key points for efficienct treatment. Our research indicated that calcium fructoborate(CF) was the best compound as...
متن کاملDosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study
Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 22 5 شماره
صفحات -
تاریخ انتشار 1995