Detection of Legionella pneumophila in Cooling Water Systems of Hospitals and Nursing Homes of Kerman City, Iran by Semi- Nested PCR

نویسندگان

  • Mohammad Ahmadinejad
  • Mohammad Reza Shakibaie
  • Kyvan Shams
  • Mohammad Khalili
چکیده

Legionella pneumophila is involved in more than 95% cases of severe atypical pneumonia. Infection is mainly by inhalation the indoor aerosols through the water-coolant systems. Because some Legionella strains may be viable but not culturable, therefore, Taq polymerase, DNA amplification and semi-nested-PCR were carried out to detect Legionella-specific 16S-rDNA sequence. For this purpose, 1.5 litter of water samples from 77 water-coolant system were collected from four different hospitals, two nursing homes and one student hostel in Kerman city of Iran, each in a brand new plastic bottle during summer season of 2006 (from April to August). The samples were filtered in the sterile condition through the Millipore Membrane Filter. DNA was extracted from membrane and used for PCR to detect Legionella spp. The PCR product was then subjected to semi-nested PCR for detection of L. pneumophila. Out of 77 water samples that were tested by PCR, 30 (39%) were positive for most species of Legionella. However, L. pneumophila was detected from 14 (18.2%) water samples by semi-nested PCR. From the above results it can be concluded that water coolant systems of different hospitals and nursing homes in Kerman city of Iran are highly contaminated with L. pneumophila spp. and pose serious concern. So, we recommend avoiding such type of coolant system in the hospitals and nursing homes. Keywords—Legionella pneumophila, water-coolant system,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

Isolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran

In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water cool‌ers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selec‌tive and nonselective media resulted in isolation of several strains of gram negative bact...

متن کامل

Efficacy of Owner‐Collected Dust Samples in the Evaluation Residential Allergen and Fungal Levels

PS 401‐8 Exposure Assessment of Legionella pneumophila in Nursing Homes of Taiwan C. Chang, N. Chen, Y. Wu, K. Ming, National Taiwan University, Taipei, Taiwan. Objective: An investigation was conducted to assess the exposure risk to Legionella pneumophila in eight nursing homes of Taiwan. Methods: Hot water (HW) and swab samples were taken from the faucets and shower heads. As for cooling tow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012