Sensitive determination of domoic acid using high-performance liquid chromatography with electrogenerated tris(2,2'-bipyridine)ruthenium(III) chemiluminescence detection.
نویسندگان
چکیده
A new sensitive determination method of domoic acid based on the chemiluminescent reaction of tris(2,2'-bipyridine)ruthenium(III) has been developed. The method exhibited good reproducibility. The relative standard deviation of six replicate measurements was 1.6% for 10 ng ml(-1). A calibration graph, based on a standard domoic acid solution, was linear over the range of 1 - 500 ng ml(-1) (coefficient of correlation, r2 = 0.9995) and the detection limit was 8 pg (signal-to-noise ratio = 3) without any preconcentration and derivatization steps. This new method was successfully applied to a real sample of blue mussels spiked with 2 microg g(-1) domoic acid.
منابع مشابه
Electrogenerated chemiluminescence derivatization reagents for carboxylic acids and amines in high-performance liquid chromatography using tris(2,2'-bipyridine)ruthenium(II).
2-(2-Aminoethyl)-1-methylpyrrolidine and N-(3-aminopropyl)pyrrolidine (NAPP) were found to be selective and sensitive derivatization reagents for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and ibuprofen were used as model compounds of carboxylic acids, and the deriv...
متن کاملColumn-switching HPLC determination of mexiletine using tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence and precolumn derivatization with divinylsulfone.
A sensitive HPLC method combined with a column-switching system and tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence (ECL) detection has been developed for the quantitative determination of mexiletine (MEX). MEX was derivatized by divinylsulfone (DVS) and then measured. The optimum conditions for the derivatization reaction were 10 µL of sample solutions, 40 mM DVS (pH 8.0), a ...
متن کاملSensitive determination method for mercury ion, methyl-, ethyl-, and phenyl-mercury in water and biological samples using high-performance liquid chromatography with chemiluminescence detection.
A sensitive determination method for mercury speciation analysis was developed. Four mercury species, mercury ion, methylmercury, ethylmercury, and phenylmercury, were complexed with emetine-dithiocarbamate (emetine-CS(2)), and then injected onto a HPLC instrument coupled with a tris(2,2'-bipyridine)ruthenium(III) chemiluminescence detection system. The emetine-CS(2) complexing agent was effe...
متن کاملConsidering the chemical energy requirements of the tri-n-propylamine co-reactant pathways for the judicious design of new electrogenerated chemiluminescence detection systems.
The introduction of a 'co-reactant' was a critical step in the evolution of electrogenerated chemiluminescence (ECL) from a laboratory curiosity to a widely utilised detection system. In conjunction with a suitable electrochemiluminophore, the co-reactant enables generation of both the oxidised and reduced precursors to the emitting species at a single electrode potential, under the aqueous con...
متن کاملElectrogenerated chemiluminescence (ECL) 79. Reductive-oxidation ECL of tris(2,2′-bipyridine)ruthenium(II) using hydrogen peroxide as a coreactant in pH 7.5 phosphate buffer solution
Hydrogen peroxide (H2O2) can be used as a coreactant to generate reductive-oxidation ECL of Tris(2,2′-bipyridine)ruthenium(II), Ru(bpy)3 (bpy = 2,2′-bipyridine), in pH 7.5 phosphate buffer solution (PBS). Although Ru(bpy)3 is adsorbed and precipitated on the electrode upon reduction of Ru(bpy)3 in aqueous solutions, ECL can still be generated and scanning electrochemical microscopy (SECM) e r o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 7 شماره
صفحات -
تاریخ انتشار 2004