Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.

نویسندگان

  • Helmut Mair
  • Joerg Sachweh
  • Bart Meuris
  • Georg Nollert
  • Michael Schmoeckel
  • Albert Schuetz
  • Bruno Reichart
  • Sabine Daebritz
چکیده

OBJECTIVE Biventricular pacing has demonstrated improvement in cardiac function in treating congestive heart failure (CHF). Two different operative strategies (coronary sinus vs. epicardial stimulation) for left ventricular (LV) pacing were compared. METHODS Since April 1999, a total of 86 patients (pts, age: 63+/-10 years) with depressed systolic LV function (mean ejection fraction 24+/-9%), left bundle-branch-block (mean QRS 182+/-22 ms) and congestive heart failure NYHA III or higher were enrolled. For biventricular stimulation coronary sinus (CS) leads were placed in 79 pts. Nine of these devices were converted to surgical epicardial LV-leads, because of CS-lead failure. In 7 patients epicardial LV-leads were initially implanted surgically, accounting for a total of 16 pts with surgical placed epicardial steroid-eluting LV-leads. For these, a limited left-lateral thoracotomy (7+/-4 cm) was used. Thirty-three (38%) pts had an indication for a defibrillator. The mean follow-up time was 16.4+/-15.4 months (0.1-45 months), representing 107.1 patient-years. RESULTS In the biventricular pacing mode, QRS duration decreased to 143+/-16 ms (P<0.001). Threshold capture of the CS-leads increased significantly compared to surgically placed epicardial leads (18 month control: 2.2+/-1.4V/0.5 ms vs. 0.7+/-0.3V/0.5 ms), which had no increase in threshold (P<0.001). At the 18 month follow-up 7 CS-leads had a threshold of >4V/0.5 ms vs. epicardial leads which were under 1.1V/0.5 ms, except for one (1.8V/0.5 ms). After CS-lead implantation 25 LV-lead related complications occurred, (failed implantation, CS-dissection, loss of pacing capture, diaphragm stimulation or lead dislodgment), vs. one dislodgement after surgical epicardial lead placement (P<0.05). Correct lead positioning (obtuse marginal branch area) was achieved in all surgical epicardial placements but only in 70% with CS-leads (P<0.03). In the follow up period, 9 pts died (4 cardiac related). Heart transplantation was necessary in 4 pts due to deterioration of the cardiomyopathy. CONCLUSIONS Surgical epicardial lead placement revealed excellent long-term results and a lower LV-related complication rate compared to CS-leads. Although, the approach via limited thoracotomy for biventricular pacing is associated with 'more surgery', it is a safe and reliable technique and should be considered as an equal alternative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robotic-Assisted Thoracoscopic Implantation of an Epimyocardial Lead for Biventricular Pacing

Biventricular pacing has been considered for the treatment of congestive heart failure secondary to dilatative cardiomyopathy and intraventricular conduction blocks [1]. In the majority of reported cases, the left ventricular lead is positioned via the coronary sinus (CS) [2]. However, the positioning of a CS lead is not always possible, due to anatomical conditions such as coronary sinus valve...

متن کامل

Temporary left ventricular pacing improves haemodynamic performance in patients requiring epicardial pacing post cardiac surgery.

OBJECTIVE In the 1990s, sequential atrio-ventricular pacing demonstrated haemodynamic benefit relative to right ventricular pacing in patients with sinus rhythm requiring pacing post cardiopulmonary bypass. The benefit of biventricular pacing has been demonstrated in non-surgical patients with severe left ventricular dysfunction. It was hypothesised that left ventricular pacing would increase c...

متن کامل

Robotically assisted left ventricular epicardial lead implantation for biventricular pacing.

OBJECTIVES Ventricular resynchronization might be achieved in a minimally invasive fashion using a robotically assisted, direct left ventricular (LV) epicardial approach. BACKGROUND Approximately 10% of patients undergoing biventricular pacemaker insertion have a failure of coronary sinus (CS) cannulation. Rescue therapy for these patients currently is limited to standard open surgical techni...

متن کامل

Optimizing CRT - Do We Need More Leads and Delivery Methods.

Cardiac resynchronization therapy (CRT) is an established therapeutic option in symptomatic heart failure with reduced ejection fraction and evidence of left ventricular (LV) conduction delay (QRS width ≥120 ms), especially when typical left bundle branch block is present. The rationale behind CRT is restoration of aberrant LV electrical activation. As there is considerable heterogeneity of the...

متن کامل

Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy.

BACKGROUND Up to 30% of patients with heart failure do not respond to cardiac resynchronisation therapy (CRT). This may reflect placement of the coronary sinus lead in regions of slow conduction despite optimal positioning on current criteria. OBJECTIVES To characterise the effect of CRT on left ventricular activation using non-contact mapping and to examine the electrophysiological factors i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2005