Rating Charts of R-22 Alternatives Flow through Adiabatic Capillary Tubes

نویسندگان

  • E. Elgendy
  • J. Schmidt
چکیده

Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental data from literature for R-22 over a wide range of both operating and geometrical parameters. Predicted lengths of adiabatic capillary tube are compared with the lengths of the capillary tube needed under similar experimental conditions and majority of predictions are found to be within 4.4% of the experimental data. Hence, the model has been applied for R-417A, R422D and R-438A and capillary tube selection charts and correlations have been computed. Finally a comparison between the selected refrigerants and R-22 has been introduced and the results showed that R-438A is the closest one to R-22. Keywords—Adiabatic flow, Capillary tube, R-22 alternatives, Rating charts, Modelling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Analysis of Capillary Tubes for CFC-12 and HFC-134a

This work presents experimental data for capillary tubes of the type commonly used as expansion devices in domestic appliances, employing CFC-12 and HFC-134a as working fluids. Capillary tubes of 0. 7, 0.8 and 1.0 millimeter internal diameter with lengths of 3 and 2 meters were tested. Condensing pressures of 18, 14, 11 and 9 bar, and subcooling ranging from 14 to 2 oc were chosen as the operat...

متن کامل

A Simulation for Predicting the Refrigerant Flow Characteristics Including Metastable Region in Non-Adiabatic Capillary Tubes

The capillary tube/suction line heat exchanger (SLHX) is widely used in small refrigeration systems. The refrigerant flowing in the SLHX experiences frictional and accelerational head losses, flashing, and heat transfer simultaneously. The simulation of refrigerant flow through SLHX is important since this will help engineers analyze and optimize the SLHX incorporated in a refrigeration system....

متن کامل

Investigation of droplet nucleation in CCS relevant systems – Design and testing of a CO2 branch of the mixture preparation device

A unique in-house designed experimental apparatus for investigation of nucleation of droplets in CCS relevant systems is being developed by our team. The nucleation is measured with the help of a rapid pressure drop within an expansion chamber. In this study, a CO2 branch representing an important part of the mixture preparation device (MPD) was designed, assembled and tested. MPD is intended f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013