Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: a radiographic study in the canine mandible.

نویسندگان

  • Gaston N King
  • Joachim S Hermann
  • John D Schoolfield
  • Daniel Buser
  • David L Cochran
چکیده

BACKGROUND Accumulating evidence suggests that alveolar crestal bone resorption occurs as a result of the microgap that is present between the implant-abutment interface in dental implants. The objective of this longitudinal radiographic study was to determine whether the size of the interface or the microgap between the implant and abutment influences the amount of crestal bone loss in unloaded non-submerged implants. METHODS Sixty titanium implants having sandblasted with large grit, acid-etched (SLA) endosseous surfaces were placed in edentulous mandibular areas of 5 American fox hounds. Implant groups A, B, and C had a microgap between the implant-abutment connection of <10 microm, 50 microm, or 100 microm, respectively, as did groups D, E, and F, respectively. Abutments were either welded (1 -piece) in groups A, B, and C or non-welded (2-piece screwed) in D, E, and F. All abutment interfaces were placed 1 mm above the alveolar crest. Radiographic assessment was undertaken to evaluate peri-implant crestal bone levels at baseline and at 1, 2, and 3 months after implant placement whereupon all animals were sacrificed. RESULTS The size of the microgap at the abutment/implant interface had no significant effect upon crestal bone loss. At 1 month, most implants developed crestal bone loss compared with baseline levels. However, during this early healing period, the non-welded group (D, E, and F) showed significantly greater crestal bone loss from baseline to one month (P <0.04) and 2 months (P < 0.02) compared with the welded group (A, B, and C). No significant differences were observed between these 2 groups at 3 months (P > 0.70). CONCLUSIONS Crestal bone loss was an early manifestation of wound healing occurring after 1 month of implant placement. However, the size of the microgap at the implant-abutment interface had no significant effect upon crestal bone resorption. Thus, 2-piece non-welded implants showed significantly greater crestal bone loss compared with 1-piece welded implants after 1 and 2 months suggesting that the stability of the implant/abutment interface may have an important early role to play in determining crestal bone levels. At 3 months, this influence followed a similar trend but was not observed to be statistically significant. This finding implies that implant configurations incorporating interfaces will be associated with biological changes regardless of interface size and that mobility between components may have an early influence on wound healing around the implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه میزان تحلیل استخوان کرستال اطراف ایمپلنت‌های Replace با دو روش Submerge و Non-submerge

Background and Aim: It is well recognized that implant treatment is common worldwide, but the approach to success is not predictable because of bone loss that occurs around the implants. Also there are many factors affecting crestal bone loss around the implants that one of them is the surgical protocol of implant installation. The purpose of this investigation was to evaluate the amount of cre...

متن کامل

Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible.

BACKGROUND Today, implants are placed using both non-submerged and submerged approaches, and in 1- and 2-piece configurations. Previous work has demonstrated that peri-implant crestal bone reactions differ radiographically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of the interface (microgap) between the implant and abutment/...

متن کامل

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Crestal Bone Loss Around Dental Implants; A Short Communication

Many studies described several parameters which are supposed to determine success or failure in longterm evaluations of dental implants. However, the relationship between crestal bone loss around implants and the location of implant-abutment connection in the bone still needs further investigations.The subgingival microgap between the implant and the abutment, which creates higher bone level re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of periodontology

دوره 73 10  شماره 

صفحات  -

تاریخ انتشار 2002