چکیده

Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determined using well-characterized HTLV-1/2-positive serum and plasma samples and routine diagnostic and blood donor samples expected to be HTLV negative, respectively. These results were compared with those for at least one of the following CE-marked assays at seven independent laboratories and the Roche Diagnostics facility in Penzberg, Germany: Abbott Architect rHTLV-I/II, Ortho Avioq HTLV-I/II Microelisa system, Abbott Prism HTLV-I/HTLV-II, and DiaSorin Murex HTLV I+II. Fujirebio INNO-LIA HTLV-I/II Score was used as a confirmatory assay. The Elecsys HTLV-I/II, Abbott Architect rHTLV-I/II, and Abbott Prism HTLV-I/HTLV-II assays detected all HTLV-1/2-positive samples (sensitivity, 100%). Sensitivity for Ortho Avioq HTLV-I/II was 98.63%. The Elecsys HTLV-I/II assay had a specificity of 99.95% in blood donor samples, which was comparable to results for the other assays (range, 99.91 to 100%). In routine diagnostic samples, the specificity of the Elecsys HTLV-I/II assay was 99.83%, compared with 99.70% for Abbott Architect rHTLV-I/II. Specificity for the Elecsys HTLV-I/II assay in potentially cross-reactive samples was 100%, compared with 99.0% for Ortho Avioq HTLV-I/II and 99.2% for DiaSorin Murex HTLV I+II. The Elecsys HTLV-I/II assay has the sensitivity and specificity to support its use as a routine screening assay for detecting HTLV infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new, fully automated immunoassay for detection of HTLV-I and HTLV-II antibodies.

Screening blood donations for human T-lymphotropic virus types I and II (HTLV-I/II) continues to be important in protecting the safety of blood products and controlling the global spread of these retroviruses. We have developed a fully automated, third generation chemiluminescent immunoassay, ARCHITECT rHTLV-I/II, for detection of antibodies to HTLV-I/II. The assay utilizes recombinant proteins...

متن کامل

SURVEY ON THE SENSITIVITY AND SPECIFICITY OF BETA ANGLE IN DIFFERENTIATING SKELETAL CLASS II AND III MALOCCLUSIONS FROM CLASS I

Background & Aims: A successful treatment in the field of medical sciences depends on an accurate diagnosis. In orthodontic diagnosis and treatment planning also analyzing the sagittal jaw base relationship is important. Various methods have been suggested for this. This study aimed to investigate the accuracy of beta angle in sagittal jaw base relationship diagnosis. Materials & Methods: In t...

متن کامل

Prevalence of Seropositivity for Human T lymphocytes Virus in Patients with Hereditary Bleeding Diseases in Population of West Azerbaijan

Background and Aims: Human T-lymphotropic virus (HTLV) is a human retrovirus which has been known to cause adult T-cell leukemia/lymphoma and some other inflammatory disorders. Patients with hereditary bleeding diseases are at high risk for these viruses. In this study, we evaluated serological HTLV-I/II infection among these patients in west Azerbaijan of Iran. Material and Methods: We stud...

متن کامل

Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum The performance of this assay was investigated previously in a multicenter study....

متن کامل

Comparison of the technical and clinical performance of the Elecsys HBsAg II assay with the Architect, AxSym, and Advia Centaur HBsAg screening assays.

South East Asia has some of the highest prevalence rates of hepatitis B virus (HBV) infection (>or=8%) in the world, and the emergence of hepatitis B surface antigen (HBsAg) mutant strains is a growing problem. Assays with the highest levels of sensitivity, including mutant detection, should be used for routine HBsAg screening. In this large multicenter study, the clinical and technical perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2017