Transverse Priority Phase Sensitive Optical Coherence Tomography

نویسندگان

  • Jeff Fingler
  • Jon Williams
  • Zahid Yaqoob
  • Changhuei Yang
  • Richard C. Haskell
  • Harvey Mudd
  • Valery V. Tuchin
  • Joseph A. Izatt
  • Scott E. Fraser
  • Richard Haskell
  • Scott Fraser
چکیده

A variation on the standard time domain optical coherence tomography (TDOCT) system is presented. Using an inexpensive piezoelectric stack to modulate the reference mirror position, the amplitude and phase of the sample reflection is determined without scanning. With the primary scan in the transverse direction, en face and B-scan OCT images can be readily produced with phase information. This project plans to use the dynamic phase information to add an extra level of contrast to the images, based on the motion of the scatterers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double common-path interferometer for flexible optical probe of optical coherence tomography

A flexible curled optical cord is useful for a common-path optical coherence tomography (OCT) system because a bending-insensitive arbitrary length can be chosen for the endoscopic imaging probe. However, there has been a critical problem that the partial reflector needs to be placed in between the sample and the objective lens. It limits the structure design of optical probe and leads to a low...

متن کامل

Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography. II. Instrument and results.

We describe an instrument for measuring the magnitude of birefringence of tomographic images and the principal directions of axes that use thermal-light polarization-sensitive optical coherence tomography. The instrument permits full-field measurements with an axial resolution of 1.5 microm and a transverse resolution limited by diffraction. We obtained a sensitivity of 84 dB, limited by shot n...

متن کامل

Optical Phase Space Contours

Advances in optical coherence tomography (OCT) rely on the availability of broadband light that is spatially coherent. We present a technique to characterize coherence properties of broadband light using optical phasespace contours in transverse momentum and position. We demonstrate that these contour plots can be directly measured by a simple heterodyne imaging scheme possessing high dynamic r...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Mobility and transverse flow visualization using phase variance contrast with spectral domain optical coherence tomography.

Phase variance-based motion contrast is demonstrated using two phase analysis methods in a spectral domain optical coherence tomography system. Mobility contrast is demonstrated for an intensity matched Intralipid solution placed without flow within agarose wells. Vasculature oriented transversely to the imaging direction has been imaged for 3-4 dpf in vivo zebrafish using the phase variance co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016