Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma.

نویسندگان

  • J Jaouhari
  • F Schiele
  • S Dragacci
  • P Tarallo
  • J P Siest
  • J Henny
  • G Siest
چکیده

We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve for method is linear between 0.3 and 17.6 nmol/L (1.9 and 100 micrograms/L). Interassay CV over the range 0.9 to 14.8 nmol/L (5.3 to 84 micrograms/L) is 7.5% to 11.7%. Analytical recovery is 105% +/- 5% (mean +/- SD). The measurement, which is adapted to microtiter plates, requires only 20 microL of serum and 5 h. The coefficient of correlation between the concentrations measured by this method and by a commercially available radioimmunoassay kit (CIS Biointernational) is 0.91. Osteocalcin can be measured in serum or heparinized plasma. Hemolysis (174 mumol/L hemoglobin) reduces osteocalcin concentration by 54%. High concentrations of triglycerides (7 mmol/L) give an overestimation of 63%. Serum concentrations of osteocalcin measured in 130 healthy subjects (ages 15-64 years) and 86 children (ages 4-14 years) were 1.4 +/- 0.8 and 4.0 +/- 1.5 nmol/L (8.1 +/- 4.6 and 22.5 +/- 8.6 micrograms/L), respectively (mean +/- SD).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A monoclonal-antibody enzyme immunoassay for detection of hepatitis B surface antigen with use of a biotin-avidin system.

In this solid-phase two-site enzyme immunoassay for hepatitis B surface antigen (HBsAg), three monoclonal anti-HBs are used: 5D3 (IgM) is immobilized on plastic beads; 5C3 (IgG2a) and 5C 11 (IgG1), labeled with biotin, are used as the first conjugate. Horseradish peroxidase covalently linked to avidin is the second conjugate. First, serum or plasma is incubated with the antibody-coated bead and...

متن کامل

Enzyme linked immunosorbent assay for determination of amlodipine in plasma.

Amlodipine is a calcium channel antagonist of the dihydropyridine group. It is effective for treating hypertension, chronic stable angina, and vasospastic angina. However, it is difficult clinically to pinpoint the maximum dosage for antihypertensive activity of the drug without having parallel data on the plasma drug concentrations. The methods for assaying amlodipine are either gas chromatogr...

متن کامل

New fluorometric enzyme immunoassay for 17beta-estradiol by homogeneous reaction using biotinylated estradiol.

A new fluorometric enzyme immunoassay for 17beta-estradiol (E2) using biotinylated estradiol (BE) as a probe ligand, is described. In this method, E2 is detected indirectly by a solid-phase avidin-biotin binding assay, in which the biotin is immobilized on a microtiter plate (biotin-plate). After the competitive reaction between E2 and BE for the anti-E2 antibody in solution, the free E2 and BE...

متن کامل

Adsorption of avidin on microfabricated surfaces for protein biochip applications.

The adsorption of the protein avidin from hen egg white on patterns of silicon dioxide and platinum surfaces on a microchip and the use of fluorescent microscopy to detect binding of biotin are described. A silicon dioxide microchip was formed using plasma-enhanced chemical vapor deposition while platinum was deposited using radiofrequency sputtering. After cleaning using a plasma arc, the chip...

متن کامل

DNA enzyme immunoassay: general method for detecting products of polymerase chain reaction.

We developed a new colorimetric method, DNA enzyme immunoassay (DEIA), for detecting specific hybrids of complementary nucleic acids and applied it to the detection of hepatitis B virus (HBV) DNA amplified from serum samples by means of the polymerase chain reaction (PCR) technique. The method is based on the ability of an anti-DNA monoclonal antibody to discriminate between single-stranded and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 10  شماره 

صفحات  -

تاریخ انتشار 1992